| Wired Network Connection Specifications |
| Ports |
| Network Analysis Ports |
2 RJ-45 10/100/1000BASE-T Ethernet Small Form-factor Pluggable (SFP) 100/1000BASE-X Ethernet Enhanced Small Form-factor Pluggable (SFP+) 10GBASE-X Ethernet |
| Management Port |
RJ-45 10/100/1000BASE-T Ethernet |
| Supported SFP+ Modules |
100BASE-FX - 1300 nm 1000BASE-SX - 850 nm 1000BASE-LX - 1310 nm 1000BASE-ZX - 1550 nm |
| Fault Tolerance |
RJ45 Ports are designed to withstand a maximum of 100 volts. |
| USB Ports |
Three USB 2.0 ports |
| eSATA Port |
eSATA port for connecting external hard drive |
| Video Port |
Standard VGA port for connection to monitor or projector |
| Cables |
| Cable Types |
100 Ohm UTP and ScTP category 5, 5E, 6, ISO/IEC Class C, D, E |
| Cable Length Measurement |
Measurable cable lengths are from 3 feet (0.9 meters) to 500 feet (152 meters). Accuracy: ± 6 feet (± 2 meters). Length measurement is based on Nominal Velocity of Propagation (NVP) for selected cable type. |
| Wireless Network Connection Specifications |
| Wireless Antennas |
| Internal Wireless Antennas |
Seven internal 2.4 GHz, 1.1 dBi peak, 5 GHz 3.2 dBi peak antennas. |
External Omni-directional Antenna |
Antenna, WLAN, omnidirectional, 2.4 & 5 GHz 802.11 A/B/G, 50 Ω. Gain: 2.1 dBi (2.45 GHz) 2.4 dBi (4.9 GHz), 2.6 dBi (5.25 GHz), 2.5 dBi (5.875 GHz). |
| External Antenna Connector |
Reverse SMA |
| Data Rate |
11a: 6/9/12/24/36/48/54 Mbps 11b: 1/2/5.5/11 Mbps 11g: 6/9/12/24/36/48/54 Mbps 11n (20 MHz): MCS0-23, up to 216 Mbps 11n (40 MHz): MCS0-23, up to 450 Mbps |
| Operating Frequency |
2.4000 ~ 2.472 GHz (Industrial Scientific Medical Band) 5.180 ~ 5.825 GHz |
| Security |
64/128-Bit WEP Key, WPA, WPA2, 802.1x |
Transmit Output Power (Tolerance: ±1.5 dBm) |
802.11b: 18 dBm 802.11b: 18 dBm 802.11g: 17 dBm 802.11a: 11 dBm 802.11n: 2.4 GHz:17 dBm 802.11n: 5 GHz:13 dBm |
Receive Sensitivity (Tolerance: ±2 dBm) |
802.11a: 10% PER -78 dBm 802.11b: 8% PER -90 dBm 802.11g: 10% PER -80 dBm 802.11n: 2.4 GHz 10% PER -72 dBm@HT20<br< a="">> -70 dBm@HT40<br< a="">> 802.11n: 5 GHz 10% PER -70 dBm@HT20<br< a="">> -63 dBm@HT40> |
Power Consumption (Typical) |
Transmitting (Legacy mode, HT20 mode): 870 mA @5 GHz, 700 mA @2.4 GHz Transmitting (HT40 mode): 900 mA @5 GHz, 750 mA @2.4 GHz Receiving (Legacy mode, HT20 mode): 550 mA @5 GHz, 520 mA @2.4 GHz Receiving (HT40 mode): 610 mA @5 GHz, 600 mA @2.4 GHz. |
| General Specifications |
| Physical Specifications |
| Dimensions |
9.45" x 12.43" x 2.03" (240mm x 315.7mm x 51.6mm) |
| Weight |
5.6lb. (2.5 kg) with batteries; 4.5lb. (1.8 kg) without batteries |
| Display |
Color active matrix TFT LCD 1024 x 768 pixels LED backlight Touch panel with 2 touch points |
| Security |
Kensington security slot on rear panel for connection of security cable |
| Environmental Specifications |
| Operating Temperature |
10°C to 30°C (50°F to 86°F) with up to 95% Relative Humidity 0°C to 50°C (32°F to 122°F) with up to 75% Relative Humidity |
| Storage Temperature |
-40°F to +160°F (-40°C to +71°C) |
| Shock and Vibration |
Meets requirements of MIL-PRF-28800F for Class 3 equipment |
| Safety |
EN 61010-1 2nd Edition |
| Altitude |
4600m (15000 ft) on batteries |
| Electrical Specifications |
| AC Adapter Input |
100V – 240V, 50/60Hz, 1.5A |
| AC Adapter Output |
19VDC, 4.74A, 90W |
| Battery |
Two user-replaceable, rechargeable, 45 Watt-hour, lithium-ion battery packs |
| Battery Operating Time |
3 hr. (typical) |
| Battery Charge Time |
3 hr. (typical). Charge time depends on residual battery charge |
| Standards and Compliance Specifications |
| Supported Network Standards |
IEEE 10BASE-TX IEEE 100BASE-TX IEEE 1000BASE-TX IEEE 1000BASE-X IEEE 10GBASE-X |
RFCs: 1213, 1239, 1285, 1512, 1513, 1643, 2108, 2115, 2127, 2515, 2819, 3592, 3895, 3896, 4188, 4502 |
| Compliance Statements |
| EMC |
Complies with IEC/EN61326-1:2006, class A |
| Safety |
Complies with IEC/EN 61010-1:2001, CAN/CSA C22.2 No. 61010-1-04, ANSI/UL 61010-1:2004, EN/IEC 60825-1:2007, EN/IEC 60825-2:2004+ A1:2007 |
| Telephone |