Fluke

  • Filter
Created on: 14 February 2014

Battery-powered dual Hall-effect, clamp-on probe measures dc current from 1-1000A; ac current from 1-600A ac rms Measures ac and dc current down to 1 amp with specified accuracy and is useable to 0.5A Output is 1 mV per amp dc or ac Jaws accept conductor size of 1 X 750 MCM ( 30 mm/1.18 in. diameter) or 2 X 500 MCM (2 X 25 mm/.98 in.) AC and DC accuracy: ± (2.0% of reading + 0.5A)

Created on: 14 February 2014

Current Range: 100mA to 1000 Arms Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output Bandwidth: 5Hz to 100kHz Working Voltage: 600V AC rms Maximum Conductor Size: 54 mm (2.13 inch) diameter Safety Rating: 600V rms. CAT III per IEC 1010-02-032

Created on: 14 February 2014

Current Range: 1 to 600 A DC or AC Peak Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A) Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A Frequency Range: 40 Hz to 400 Hz Working Voltage: 600 V AC rms Maximum Conductor Diameter: 34 mm (1.34 inch) Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Created on: 14 February 2014

Current Range: 0.1 to 100A DC or 0.1 to 70A AC Basic Accuracy (DC to 1kHz): 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading Output Signal: 10A range: 100mV/A | 100A range: 10mV/A Bandwidth: 1Hz to 20kHz Working Voltage: 600V AC rms Maximum Conductor Size: 1.8 mm (.46 inch) diameter Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Created on: 14 February 2014

DC voltage measurement to verify 24 V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp Output mA signal enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators Voltage output linear ramp or 25% step output Automatically change the voltage output for remote testing

Created on: 14 February 2014

Measure 4 to 20 mA signals without ”breaking the loop” just like the innovative and popular Fluke 771 Process Milliamp Clamp meter Source 4 to 20 mA signals for testing control system I/O or I/Ps Simulate 4 to 20 mA signals for testing control system I/O Measure 4 to 20 mA signals with in-circuit measurement Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters Source mA output signals in a linear ramp or 25 % step output– Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life

Created on: 14 February 2014

Measure mA signals for PLC and control system analog I/O Measure 4 to 20 mA output signals from transmitters without breaking the loop Best in class 0.2 % accuracy Resolution and sensitivity to 0.01 mA Hold function captures and displays changing measurements Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatic power off after 15 minutes and 2 minute automatic off for backlight and spotlight

Created on: 14 February 2014

Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements Small body and jaws fit perfectly in your hand and into tight places Handy 'Display Hold' button keeps measurements on the display Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch) Large, backlit display (on most models) is easy-to-see Auto shut-off maximizes battery life so the meter works when you need it Three year warranty