Fluke

  • Filter
Category: Connectors
Created on: 12 February 2014

Shielded four conductor cable terminated with a 9-socket D-subminiature connector and a 9-pin D-subminiature connector. Provides interconnection and pin translation between a Fluke 743 Documenting Process Calibrator and a Hewlett Packard HBSW-8200 Bar Code Wand. Overall length approximately 15 cm One year warranty

Category: Connectors
Created on: 12 February 2014

Very accurate current shunt to use for verification and calibration of process control loops. Can be used with accurate voltmeters for calibration purposes Can be used with Fluke 74X series in mA/mA applications (74X will display mA/mA automatically) One year warranty

Created on: 12 February 2014

Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable

Created on: 12 February 2014

Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable

Created on: 12 February 2014

Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable

Created on: 12 February 2014

Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)

Created on: 12 February 2014

Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)

Created on: 12 February 2014

Measuring Range selectable per software:0.01A to 1A0.1A to 10A Peak current for sinusoidal currents:3.7A to 37A Intrinsic error: 0.5% Frequency Range: 40Hz to 10kHz Operating Voltage: 300V CAT IV Phase Error: 0.5° Jaw Opening: <15mm diameter or 15x17mm bus bars Errors in % of measuring range at 23°C ± 2K; 74°F±2K, for 48 to 65Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)