Fluke
Kit Includes: 50 Ohm BNC insulated feedthrough terminator 50 Ohm BNC terminator with 10:1 signal attenuation 1 Ohm current shunt for current measurements Safety-designed BNC cable, 1.5 m (5 ft) Insulated BNC (f) to 4mm-banana plug adapter Dual 4 mm banana receptacles (1 red, 1 black)
Provides RPM readings
Current range: 0.01 – 10A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm)
Current range: 0.1 – 40A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm)
Current range: 0.5 – 1-0A Accuracy: 1% RDG +/- 0.5% FS Frequency response: 5 kHz Length: 7/16” (1 cm)
For general purpose applications Teflon tape insulation Not suitable for liquid immersion Shipped with the 80TK, Fluke 50 Series Measurement range: -40 °C to 260 °C (-40 °F to 500 °F) Accuracy: ± 1.1 °C (2.0 °F) over the range of 0°C to 260°C (32°F to 500°F) Maximum Temperature of Insulation: 260°C (500°F)
For general purpose applications Type-K thermocouple surface, air and non-caustic gases Measurement range:-40°C to 260 °C 6 inch Stainless Steel Probe
Type-K thermocouple with tapered tip for use in air, non-caustic gas and surface applications Measurement range:-40 to 816ºC