Hioki

  • Filter
Created on: 17 May 2014

High Precision DC to 1MHz/50A, 500kHz/200A AC/DC Pull-through Current Sensors with ±0.05% Basic Accuracy Hioki pull-through AC/DC current sensors are best-in-class devices for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT6862 is a DC to 1MHz/50A sensor, and the CT6863 is a DC to 500kHz/200A sensor, and both are ideal for capturing current signals from switching power supplies, inverters, power conditioners, etc.

Created on: 17 May 2014

Wide band DC to 10 MHz/150A AC/DC Current Probe for Oscilloscopes Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The 3274 supports wide DC to 10 MHz bandwidth signals and 150A of continuous high input, and is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. Use optional power supply 3269 or 3273 to drive the current probe when power from the Memory HiCorder or oscilloscope is not available.

Created on: 17 May 2014

Wideband DC to 2 MHz/500A AC/DC Current Probe for Oscilloscopes Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The 3275 supports wide DC to 2 MHz bandwidth signals and 500A of continuous high input, and is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. Use optional power supply 3269 or 3273 to drive the current probe when power from the Memory HiCorder or oscilloscope is not available.

Created on: 17 May 2014

Wideband DC to 100 MHz/30A AC/DC Current Probe for Oscilloscopes Hioki wide frequency current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The 3276 offers a wide DC to 100 MHz bandwidth and 30A of continuous input, and is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. Use optional power supply 3269 or 3273 to drive the current probe when power from the Memory HiCorder or oscilloscope is not available.

Created on: 17 May 2014

Wideband DC to 50 MHz/30A AC/DC Current Probe for Oscilloscopes Hioki flat bandwidth current probes are best-in-class current sensors for use with Memory HiCorders and high performance oscilloscopes. The 3273-50 offers a wide DC to 50 MHz bandwidth and 30A of continuous input, and is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. Use optional power supply 3269 or 3273 to drive the current probe when power from the Memory HiCorder or oscilloscope is not available.

Created on: 17 May 2014

300 mΩ to 30 Ω/30V Portable Battery Tester for Testing Compact Storage Batteries for Mobile Devices Hioki portable battery testers support the maintenance of UPS and storage batteries critical to the life support of all businesses. The 3551 tests high-capacity alkali and lead-acid storage batteries used in mobile devices, up to 30V. The 3555 cannot make PASS/FAIL judgments for lithium-ion batteries due to the extremely small magnitude of the changes in their internal resistance. For applications involving measurement of batteries with low internal resistance, for example lead acid batteries, use the Battery HiTester 3554.

Created on: 17 May 2014

300 mΩ to 3Ω/20V DC Battery Resistance Testers for High-Speed Production Line Testing of Small Battery Packs for Mobile Devices Hioki benchtop battery testers support simultaneous high-speed measurement of internal resistance and battery voltage for the ever-expanding production lines of increasingly larger lithium-ion low resistance batteries, and other battery packs for high voltage applications. The 3561 is a high-speed device ideal for the production line testing of small secondary batteries. 3561: Basic model 3561-01: with GP-IB • Measurement leads are not included. Purchase the appropriate lead option for your application separately. • The male (system side) of the EXT I/O connector is also available. Please inquire with your HIOKI distributor.

Created on: 17 May 2014

3 mΩ to 3 Ω/60V Handheld Battery Tester for Diagnosing and Managing UPS Batteries Hioki portable battery testers support the maintenance of UPS and storage batteries critical to the life support of all businesses. The 3554 sets the standard for assessing the deterioration and remaining life of lead-acid batteries by giving a complete diagnosis via battery resistance testing. The thresholds for determining the pass/fail condition of a battery depends on the specifications and standards of the battery manufacturer, battery type, capacity, etc. It is important and necessary to always conduct battery testing against the internal resistance and terminal voltage of a new or reference battery. In some cases, it may be difficult to determine the deterioration state of sealed lead acid batteries which demonstrates smaller changes in internal resistance than traditional open type (liquid) lead-acid or alkaline batteries.