| AC Watt (50 or 60 Hz, PF 0.5 to 1, CT=1) |  
| Range  | Resolution  | Accuracy of Readings  |  
| 6800+6801  |  6800+6802  |  6800+3007  |  
| 5.0 – 999.9W | 0.1W | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts |  
| 1.000 – 9.999 KW | 0.001 KW | ±1% ± 8 dgts | ±1% ± 8 dgts | ±1% of VA Range ±8dgts |  
| 10.00 – 99.99 KW | 0.01 KW | ±1% ± 8 dgts | ±1% ± 8 dgts | ±1% of VA Range ±8dgts |  
| 100.0 – 999.9 KW | 0.1 KW | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts |  
| 1000 – 9999 KW | 1 KW | ±1% ± 8dgts | ±1% ± 8dgts | ±1% of VA Range ±8dgts |  
| 0.000 – 9.999MW | 0.001MW | – | ±1% ± 8 dgts | ±1% of VA Range ±8dgts |  | 
| 
| AC Current( 50 or 60Hz, Auto Range,True RMS,Crest Factor<4,CT=1) |  
|  | Range  | Resolution  | Accuracy of Readings  |  
|  6830+6801  (Overload Protection AC200A)  | 0.050 – 9.999A | 0.001A | ±0.5% ± 5dgts |  
| 10.00 – 60.00A | 0.01A | ±0.5% ± 5dgts |  
| 60.00 – 99.99A | 0.01A | ±1.0% ± 5dgts |  
| 6830+6802  (Overload Protection AC2000A)  | 0.04 – 10.00A | 0.01A | – |  
| 0.4A – 100.0A | 0.1A | ±0.5% ± 5dgts |  
| 4.0 – 1000.0A | 1A | ±0.5% ± 5dgts |  
| 6830+3007  (Overload Protection AC3500A)  | 4 – 300A | 0.1A | ±1% of Range ±5dgts |  
| 300.0 – 999.9A | 0.1A | ±1% of Range ±5dgts |  
| 1000 – 3000A | 1A | ±1% of Range ±5dgts |  | 
| 
| AC Voltage (50 or 60 Hz, Auto Range, True RMS, Crest Factor<4) |  
| Range  | Resolution  | Accuracy of Readings  | Range  | Resolution  | Accuracy of Readings  |  
| 4.0V – 500.0 (Phase to Neutral) | 0.1V | ± 0.5% ± 5dgts | 4.0V –600.0V (Phase to phase) | 0.1V | ± 0.5% ± 5dgts |  | 
| 
| Harmonics of AC Voltage in % and in Magnitude (1 to 99th order, minimum voltage at the 50 or 60 Hz>AC 80V) |  
| Range  | In Percentage  | In Magnitude  |  
| Resolution  | Accuracy of readings  | Resolution  | Accuracy of readings  |  
| 1 – 20 th | 0.1% | ±2% | 0.1 V | ±2% ±0.5V |  
| 21 – 49 th | 4% of reading ±2.0% | 4% of reading ±0.5A |  
| 50 – 99 th | 6% of reading ±2.0% | 6% of reading ±0.5A |  | 
| 
| Harmonics of AC Current in % and in Magnitude Model 6830+6801(100A)(1 to 99th order, minimum current at 50 or 60 Hz is greater than 10% of the range) |  
| Range  | In Percentage  | In magnitude  |  
| Resolution  | Accuracy of reading  | Resolution  | Accuracy of reading  |  
| 1 – 10 th | 0.1% | ±0.2 of reading ±1% | 0.1mA / 0.1A | ±0.2% of reading ±7dgts |  
| 11 – 20 th | ±2% of reading ±1% | ±2% of reading ±7dgts |  
| 2 1 – 50 th (A range) | ±5% of reading ±1% | ±5% of reading ±7dgts |  
| 2 1 – 50 th (mA range) | ±10% of reading ±1% | ±10% of reading ±7dgts |  
| 5 1 – 99 th | ±35% of reading ±1% | ±35% of reading ±7dgts |  | 
| 
| Model 6830+6802(1000A);6830+3007(3000A)(1 to 99th order, minimum current at the 50 or 60 Hz>20A) |  
| Range  | In Percentage  | In Magnitude  |  
| Resolution  | Accuracy of reading  | Resolution  | Accuracy of reading  |  
| 1 – 20 th | 0.1% | ±2% | 0.1A(6802) / 0.3A(3007) | ±2% of reading ±0.4A/0.6A |  
| 21 – 49 th | 4% of reading ±2.0% | ±4% of reading ± 0.4A/0.6A |  
| 50 – 99 th | 6% of reading ±2.0% | ±6% of reading ± 0.4A/0.6A |  | 
| 
| Total Harmonic Distortion |  
| Range  | Resolution  | Accuracy(6801)  | Accuracy(6802)  | Accuracy(3007)  |  
| 0.0 – 20% | 0.1% | ±1% | ±2% | ±2% |  
| 20 – 100% | 0.1% | ±3% of reading ±5% | ±6% of reading ±1% | ±6% of Range ±1% |  
| 100 – 999.9% | 0.1% | ±10% of reading ±10% | ±10% of reading ±1% | ±10% of Range ±1% |  | 
| 
| Peak Value of Ac Voltage or AC Current ,VT=1 |  
| Range  | Sampling Time | Accuracy of reading  |  
| 50Hz | 39 μS | ±5% ±30digits |  
| 60Hz | 33 μS | ±5% ±30 digits |  | 
| 
| Crest Factor (C.F.) of ACV or ACA ,VT=1 |  
| Range  | Resolution  | Accuracy of reading  |  
| 1.00 – 99.99 | 0.01 | ±5% ±30digits |  | 
| 
| Range  | Resolution  | Accuracy of reading  |  
| 45 – 65Hz | 0.1Hz | 0.1Hz |  | 
| 
| Range  | Resolution  | Accuracy of reading  |  
| 0.00 – 1.00 | 0.01 | ± 0.04 |  | 
| 
| Range  | Resolution  | Accuracy of reading  |  
| -180 。 to 180 。 | 0.1 。 | ± 1 。 |  | 
| 
| Conductor Size (6801) | 約30mm (approx) |  
| Conductor Size (6802) | 約55mm(approx.), 64 X 24mm(Bus Bar) |  
| Battery Type | 1.5V SUM-3 x 8 |  
| Display | Dot Matrix LCD with backlight |  
| Power Consumption | 140mA (approx.) |  
| External DC Input | DC 12V adaptor (for safety purpose, the adaptor must be certified with 600Visolation protection) |  
| LCD update rate | 1 times / sec |  
| No. Of Samples/Period | 1024 |  
| Operating Humidity | < 85% relative |  
| Operating Temperature | -10°C to 50°C |  
| Storage Humidity | < 75% relative |  
| Storage Temperature | - 20°C to 60°C |  
| Weight(6830) | 1160g |  
| Weight(6801) | 200g |  
| Weight(6802) | 600g |  
| Dimension(6830) | 257 (L) x 155 (W) x 57 (H) mm ,10.1"(L) x 6.1" (W) x 2.3" (H) |  
| Dimension(6801) | 210 (L) x 62 (W) x 36 (H) mm ,8.3 " (L) x 2.5" (W) x 1.4" (H) |  
| Dimension(6802) | 244 (L) x 97 (W) x 46 (H) mm ,9.6 " (L) x 3.8" (W) x 1.8" (H) |  
| Accessories | Test leads x 4,alligator clips x 4,Carrying bag x 1,Users manual x 1,Batteries 1.5V x 8 |  |