Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 18 February 2014

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to    five minutes when the “PUSH BUTTON SWITCH”    and “TIMER ON BUTTON” are pressed together.  ● This will keep test “ON” for the duration of the timer.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 163(L) × 100(W) × 50(D)mm Weight (battery included) Approx. 460g Power source 1.5V (AA) × 6 Safety standards IEC 1010 CAT II 30V

Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 175(L) × 85(W) × 75(D)mm Weight (battery included) Approx. 600g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT IV 30V   EN 61326-1

Created on: 18 February 2014

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories    for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 170(L) × 165(W) × 92(D)mm Weight (battery included) Approx. 1000g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 150V EN 61326-1

Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 210(L) × 210(W) × 100(D)mm Weight (battery included) Approx. 1370g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 30V EN 61326-1

Created on: 18 February 2014

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories    for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx Open circuit indication LED will be unlit Dimensions 205(L) × 90(W) × 55(D)mm Weight (battery included) Approx. 514g Power source 1.5V (AA) × 6 Safety standards EN 61010-1 CAT III 30V EN 61326-1

Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac(40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1500g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 30V EN 61326-1

Created on: 18 February 2014

● Microprocesser-controlled. ● Measures earth resistance in three ranges : 40Ω, 400Ω, 4kΩ.● Capable of measuring earth voltage.● 3 ¾ digit (4000 counts).● LCD backlight display.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Data hold function.● Relative function.● Auto power-off function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS Measuring ranges Earth Resistance 0~40Ω / 0~400Ω / 0~4kΩ Earth Voltage 0~400V (40~500Hz) Accuracy Earth Resistance ±(2%rdg+3dgt) Earth Voltage ±(2%rdg+3dgt) Earth resistanceresolution 0~40Ω : 0.01Ω 0~400Ω : 0.1Ω 0~4kΩ : 1Ω Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Dimensions 163(L) x 102(W) x 50(D)mm Weight (battery included) Approx. 440g  Power source 1.5V (AA) x 6 Safety standards EN 61010-1 CAT IV 400V EN 61326-1 EN 61557-1 EN 61557-5

Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Auto power off function.● The timer operates automatically for about three to five minutes   when the "PUSH BUTTON SWITCH" and "TIMER ON BUTTON"   are pressed together. This will keep test "ON" for the duration of the   timer.● Timer for test function (count 3-5 minutes).● Battery operated.● Data hold function.● Small and light weight.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac (40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistanceresolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA. ...