Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed   during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.     SPECIFICATIONS       Test voltage (DC V) 1kV   /   2.5kV     /     5kV     /   10kV Measuring ranges (Auto-Ranges) 0-50GΩ / 0-125GΩ / 0-250GΩ / 0-500GΩ Accuracy 0-50GΩ : ±3% rdg 50-500GΩ : ±5% rdg Dimensions 170(L) × 120(W) × 95(D)mm Weight (battery included) Approx. 1030g Power source 1.5V(AA) × 8 Safety standard EN 61010-1 EN...

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.     SPECIFICATIONS Test voltage (DC V) 0.5kV   /   1kV   /   2.5kV   /     5kV Measuring ranges (Auto-Ranges) 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ Accuracy ±5% rdg Output power limit 1W Sealed with gasket ˇ Insulation resistance between electrical circuit and housing : 2000MΩ / 2000V ˇ Withstand voltage: 7000 Vac for one min. between electrical circuit and case ˇ Operation temperature -15°C to 55°C Operation-humidity ...

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Measures insulation time test.● Bargraph indicates test voltage; rise and decay can be observed    during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.     SPECIFICATIONS       Test voltage (DC V) 1kV     /   2.5kV   /     5kV     /   10kV Measuring ranges (Auto-Ranges) 0-50GΩ / 0-125GΩ / 0-250GΩ / 0-500GΩ Accuracy ±5% rdg Output power limit 1W Sealed with gasket ˇ Insulation resistance between electrical circuit and housing : 2000MΩ / 2000V ˇ Withstand voltage: 7000 Vac for one min. between electrical circuit and case ...

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● Fully protected: crow bar.● Carry case.● EEPROM calibration.     SPECIFICATIONS             Test voltage (DC V) 0.5kV /   1kV   /   2.5kV   /   5kV Measuring ranges (Auto-Ranges) 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ Accuracy ±3% rdg Output power limit 50uA to 100uA (1W) Live warning > 500V AC Operation temperature 0°C to 40°C Operation-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D)mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries Safety standard EN 61010-1 EN 61326-1

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● Fully protected: crow bar.● Carry case.● EEPROM calibration.     SPECIFICATIONS             Test voltage (DC V) 1kV   /   2.5kV   /     5kV   /     10kV Measuring ranges (Auto-Ranges) 0-50GΩ / 0-125GΩ / 0-250GΩ / 0-500GΩ Accuracy ±3% rdg Output power limit 50uA to 100uA (1W) Live warning > 500V AC Operation temperature 0°C to 40°C Operation-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D)mm Weight (battery included) Approx. 3600g Power source 1.5V “C”× 8 Alkaline batteries Safety standard EN 61010-1 EN 61326-1

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bargraph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present(>500Vac or    Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.     SPECIFICATIONS             Test voltage (DC V) 0.5kV to 10kV (0.5kV increment steps) Insulation resistance (Auto ranging) 25GΩ / 0.5kV 25GΩ at 0.5kV → 500GΩ at 10kV Accuracy  ± 3% rdg ± 1 dgt Output power limit 50uA to 100uA (1W) Live warning > 500V AC ...

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● 2 ×16 characters; large intelligent LCD module.● 20 Insulation test voltages 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,    3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV,    9kV, 9.5kV, 10kV.● Ener-Save™ feature to extend battery life.● Bar-graph indicates test voltage; rise and decay can be observed.● Visual and audible warning if external voltage is present (>500Vac or Vdc.)● Insulation resistance; auto-ranging on all ranges.● Overload protection.● Low battery indicator (read time battery voltage measurement).● Measures insulation time duration of the test.● Low battery consumption.● Better than 10% accuracy on all ranges.● Auto-off.● Calculates Dielectric Absorption Ratio (DAR) automatically.● Calculates Polarization Index (PI) automatically.     SPECIFICATIONS       Test voltage From 500Vdc to 10kVdc Adjustable in 500V steps Preset buttons 1kV / 2.5kV / 5kV / 10kV Measuring ranges 800kΩ-500GΩ (auto-ranging) Accuracy ± 5% ± 2 digits ...

Created on: 18 February 2014

FEATURES ● High quality Taut Band movement.● Three insulation test voltages(DC) : 250V, 500V, 1000V.● Two continuity test on “low ohms” : 3Ω & 500Ω.● AC voltmeter with linear scale up to 600 Vac.● 200mA short circuit current for continuity.● 1mA test current on insulation test at nominal voltage.● Automatic discharge of capacitive and inductive circuit with charge stored in the circuit under test.● Live warning and display of external voltage presence.● Fuse, air gap, crowbar and overload protected.● On line battery monitoring shows if battery is ok.● Manual zero ohm adjustment.● Low battery consumption.● Mirror scale.● Push and turn locking switch for continuous and hand free testing.● Supplied with high quality test leads.● BS 16 edition.     SPECIFICATIONS    Insulation Resistance     Test voltage (DC V) 250V     /   500V   /   1000V Output voltage on open circuit Rated test voltage +10% Measuring ranges 0-100MΩ / 0-200MΩ / 0-400MΩ Mid-scale value ...