Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 21 October 2014

Bante520 is aneconomical and easy-use conductivity meter for field or laboratory applications. The meter with auto-ranging feature that can quickly measures the electrical conductivity of liquids, accuracy up to ±0.5% full scale. Features: Single point push-button calibration allows user to uses customized     calibration solution. Adjustable cell constants and temperature coefficients. Automatic Temperature Compensation ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate measured value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Hold function freezes the current displayed value for easy viewing     and recording. Help message as a operational guide to helps you understand how     to use meter. Setup menu lets user customize temperature units, date and time to     meet measurement requirements. Expanded memory stores and recalls up to 64 readings. Built-in real-time clock stamps stored...

Created on: 21 October 2014

Bante530 portable conductivity meter used for measuring the electrical conductivity and TDS of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable TDS factors, cell constants, temperature coefficients and     normalization temperature. Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use meter.   Setup menu lets user customize calibration points, stability conditions,     temperature units, date and time to meet ...

Created on: 21 October 2014

Bante531 portable conductivity meter used for measuring the electrical conductivity and salinity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable cell constants, temperature coefficients, normalization     temperature etc. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use meter.

Created on: 21 October 2014

Bante540 portable conductivity meter used for measuring the electrical conductivity, TDS, salinity and resistivity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable TDS factors, cell constants, temperature coefficients and     normalization temperature. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Help message as a operational guide to helps you understand how     to use...

Created on: 21 October 2014

DDS-W series conductivity meter are an easy-use basic meters which used for measuring the electrical conductivity of liquids. Automatic Calibration: The meters can calibrate 1 point in each of the measuring ranges.  From Setup Menu, choose calibration and immerse the electrode into standard calibration solution,press ENTER key and meter is automatically calibrated. Auto-Ranging: The meters have auto-range function for measuring conductivity. Upon immersing conductivity cell into sample solution, the meter will immediately displays the values in appropriate measurement range for accuracy.

Created on: 21 October 2014

DDS-W series conductivity meter are an easy-use basic meters which used for measuring the electrical conductivity of liquids. Automatic Calibration: The meters can calibrate 1 point in each of the measuring ranges.  From Setup Menu, choose calibration and immerse the electrode into standard calibration solution,press ENTER key and meter is automatically calibrated. Auto-Ranging: The meters have auto-range function for measuring conductivity. Upon immersing conductivity cell into sample solution, the meter will immediately displays the values in appropriate measurement range for accuracy.

Created on: 21 October 2014

Bante510 benchtop conductivity meter used for measuring the conductivity and TDS of liquids. The meter is widely used in environmental and ecological studies for monitoring the purity and concentration of water. Features: Large backlit LCD display shows mode indicators and help messages. Up to 3-point push-button calibration allows user to uses customized     calibration solutions. Auto-Ranging for conductivity and TDS measurements. Adjustable TDS factors, cell constants and temperature units. Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Automatic endpoint function freezes the stable measured values for     easy reading and recording data. Manual temperature calibration provides accurate temperature value. Help message as a operational guide to helps you understand how     to use meter.

Created on: 21 October 2014

Bante950 is a professional multi-range conductivity meter which used for measuring the conductivity, TDS, salinity and resistivity of liquids. Features: Up to 5-point push-button calibration allows user to uses customized     calibration solutions. Adjustable TDS factors, cell constants, temperature coefficients and     normalization temperature. In salinity measurement modes, selectable practical salinity (PSU) or     seawater measurement standard (ppt). Automatic Temperature Compensation (ATC) ensures highly accurate     measurements over the entire range. Manual temperature calibration provides accurate temperature value. Selectable either temperature units between degrees Celsius (°C)     and degrees Fahrenheit (°F). Selectable linear or pure water compensation modes. Calibration due reminder prompts you to calibrate the meter regularly. Automatic endpoint function freezes the stable measured values for     easy reading and recording data.