Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 * When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.

Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020, 6300, 6305, 6310, 6315

Category: Power Meter
Created on: 15 May 2014

Flicker Sensor Can measure Flicker in combination with KEW6310. For use with following model 6310

Category: Power Meter
Created on: 15 May 2014

Can measure Flicker in accordance to IEC 61000-4-15 and EN50160 standards. Using our Flicker sensor, available as optional accessory, Pst value (short term severity in 10 minutes value) and the Plt value (long term severity in 2 hours value) can be measured. • 12 kinds of Power Measurements for Power Control and Applicable to Power Quality Control including Harmonics Analysis. • One click easy-to-use operation helps complicated setting and processing of large data through the setting / analyzing software provided as accessory. • Direct communication with PC via USB cable

Category: Power Meter
Created on: 15 May 2014

12 kinds of power measurements Voltage (RMS), Current (RMS), active power, apparent power, reactive power, active energy, apparent energy, reactive energy, power factor (cos θ), frequency , demand measurement, current flowing on the neutral line(Only on 3 phase 4 wire measurement) Regenerative electric power can be measured Detection of consumption power and regenerative electric power Regenerative electric power: This is the electric power which is generated by private power generator, and is supplied to electric power company. Display 3 different data simultaneously on large screen. 4 types wiring system 1 phase - 2 wire (1ch) (2ch), (3ch) 1 phase - 3 wire 3 phase - 3 wire 3 phase - 4 wire

Category: Power Meter
Created on: 15 May 2014

Simultaneous Power & Power quality measurementsPower/ Harmonics/ Waveform/ Power quality are recorded at all CHs. (Voltage: 3ch, Current 4ch)   • Helpful support functionsQuick Start Guide, Wiring check and Sensor detection for easy and reliable measurement   • Measurement with high accuracy Guaranteed accuracy: ±0.3%rdg (energy),±0.2%rdg (voltage/ current) Complies with the International Standard IEC 61000-4-30 Class Sand the European Standard EN50160   • Remote monitoring on PC and Android deviceRemote checking of measurement in real-time is possible via Bluetooth communication.Recorded data can be saved in the supplied SD card.EN50160 report can be generated after survey by PC software.

Category: Power Meter
Created on: 15 May 2014

Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems • Voltage, Current, Power Factor and Frequency measurements • Power analysis (Active, Apparent and Reactive power) • Energy analysis (Active, Apparent and Reactive power) • Active power accuracy: ±0.3%rdg±0.2%f.s. • Automatic wiring check function to prevent incorrect connections • Large memory capability (2GB) using built-in SD card interface • Real time & remote measurements using Android application • synchronous measurements between two units of KEW 6305 • Wide selection of clamp sensors allow measurements from 0.1A to 3000A • The instrument automatically recognizes what kind of clamp sensor is connected to it

Created on: 15 May 2014

Multi-Trans How to Use Clamp your instrument around the pick-up coil of the multi-tran. Then, clamp the transformer jaws of the multi-tran on the conductor, as shown below. Multiply the reading of your clamp meter by 10 to obtain the current value measured.