Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Category: Chlorine
Created on: 18 May 2013

Features: Microprocessor based for fast and accurate measurements. EPA approved DPD method. Large LCD 45 x 25 mm display for reading convenient. Memory function stores and recalls up to 150 points. Low battery alarm and auto shut off after 10 minutes of non use.  Specifications:   Range 0 ~ 3.50 ppm Resolution 0.01 ppm Accuracy ± 0.03 + 1 digit at<2.00 ppm ± 3% FS + 1 digit at>2.00 ppm Response <5 seconds Operating 0 ~ 50 ℃, <85% RH Sample 10 ml Data memory Storage /recall up to 150 points Power DC 1.5V (UM4, AAA) battery x 4 Dimension Meter: 70 x 135 x 65 mm Weight Meter: 168 g(including battery)   Accessories: FCL Reagent strip x 50 pcs(DPD-1)  TCL Reagent strip x 50 pcs (DPD-4) Glass testing bottle x 3 Distilled water x 50 ml Clean cloth x 1 Cup x 1 Battery Carrying case

Category: Chlorine
Created on: 18 May 2013

CHLORINE METER * Free chlorine, total Chlorine measurement. * Range : 0 to 3.5 mg/L (ppm). * Range : Auto range. * Measuring principal : Photo meter method. * Light source : LED, 525 nm. * Record Max, Min. value. * 10 PCs Free and Total powder DPD are included. * Free and total 1.0 mg/L standard solution are the standard accessories. * Power : 1.5 V battery (UM-4/AAA) x 6 PCs. * The measuring method is an adaptation of the USEPA Method 330.5 and Standard Method.  

Category: pH Meters
Created on: 18 May 2013

* 0 to 14.00 pH. * ATC (auto temperature compensation).   PEN PH METER * 0 to 14.00 pH. * ATC (auto temperature compensation). * Auto calibration for pH 4, pH 7 or pH 10. * Meter with pH electrode, all in one. * IP-67, water proof. * Easy replacement for the pH electrode. * Pen type, easy carry out. * Data logger. * pH 4, pH 7 standard solution are included. * DC 1.5V battery ( UM-4, AA ) x 4, long life

Category: pH Meters
Created on: 18 May 2013

* Complete set with separate soil, spear tip pH electrode and pH 4 and pH 7 standard solution. * Complete set with separate soil, spear tip pH electrode and pH 4 and pH 7 standard solution. * Meter : 0 to 14 pH x 0.01 pH. Electrode : 1 to 13 pH. * Auto calibration for pH 4, pH 7 or pH 10. * Temp. adjustment is not necessary. * IP-65 water proof. * Build in reverse display button. * DC 1.5V battery ( UM-4, AA ) x 4, long life. * Spear tip pH electrode, ideal for penetration pH measurements into soil, meats, cheese and other type of measurements requiring sample penetration.

Created on: 18 May 2013

Feature Microprocessor based for fast and accurate measurements. Special viewing angle designed of waterproof housing IP 57 rated. It floats on water. Large LCD display pH or ORP or Conductivity or TDS or Salinity or DO and Temperature Simultaneously. Simple to calibrate by one keyboard and automatic temperature compensation(ATC), Manual Salinity(MSC) and Altitude(MAC) Compensation. Multi-functions with Data-hold, Max/Min and shows PTS after calibration. Degree ℃/℉ are switchable. Low battery and consumption indicator. Auto power shut off after 10 minutes of non use. Easy to replace electrode module, and the type of electrode would be recognized automatically and shown in display during insertion. Specifications     7200 7011 7021   pH mV Temp.  Cond. TDS Salt Temp. Range  -2 ~ 16.00  -1000 ~ 1000  0 ~ 90 ℃  0 ~ 2000 μS  2.00~20.00 mS  0 ~ 1300 ppm  1.30 ~ 13.00 ppt  0 ~1000 ppm  1.00 ~ 12.00 ppt  0 ~ 90 ℃ Accuracy  ± 0.01 + 1digit  ±2 + 1digit  ± 0.2 + 1digit ± 2% FS ( Cond., TDS, Salt)  ± 0.2 ℃ +...

Created on: 18 May 2013

DO-31P -1000 point data memory -LCD display for all parameters -Salinity and atmosphereic pressure correction -Data print-out capability -Automatic Time interval Measurement -Water proof housing -Data hold function and auto power off

Created on: 18 May 2013

Model PAL-ACID2  (Tartaric Acid ) Cat.No. 4642 Measurement Range Tartaric acid concentration 1.0 to 40.0(g/l) (Total-tartaric acidity conversion [g/l] ) Minimum Indication 0.1(g/l) Repeatability 1.0 to 20.0(g/l) ±0.5(g/l) 20.1 to 40.0(g/l) ±1.0(g/l) Measurement Temperature 10 to 40°C (Automatic Temperature Compensation ) Ambient Temperature 10 to 40°C Optional •Micropipette : RE-79401 •Calibration solution : RE-130002 •Quinone reagent solutions 10 pcs : RE-99432 •Quinone reagent solutions 20 pcs : RE-99430 •Quinone reagent solutions 50 pcs : RE-99431The quinone reagent has a shelf life of 3 months, and the calibration solution has 1 year (unopened) from the date of purchase. Power Supply 2 × AAA Batteries Dimensions & Weight 55(W)×31(D)×109(H)mm, 100g (Main Unit only)