Basic T&M

The GW Instek Basic Test & Measurement instruments can be divided into 4 groups: Digital Meters, LCR Meters, Safety Testers, and Specific Application T&M Instruments.

In the Digital Meter group, we provide 6 ½ digit, 5 ½ digit, 4 ½ digit, as well as 3 ½ digit benchtop multimeters, 4 ½ and lower digit handheld multimeters as well as a range of DC milliohm meters and AC power meter.

LCR Meter includes two main series, LCR-8000G and LCR-800 Series. Depending on the model, these series feature frequency of 2kHz ~ 10MHz, and accuracy of 0.05% ~ 0.1%.

For Safety testing, GPT-9900 and GPT-9800 Series safety testers provide you with a safe and quick measurement tool for AC/DC withstanding voltage tests, insulation resistance tests, and ground continuity tests. GLC-9000 leakage current tester supports all the major leakage current test standards for medical and general electrical equipment.

In order to provide a complete "one stop shopping" solution, 120MHz ~ 2.7GHz high precision frequency counters, automatic distortion meters and A.C. millivolt meters are also provided in this product line.

  • Filter
Created on: 30 October 2014

Features: ※ Auto Range ※ Auto Power Off ※ Max Hold ※ True RMS Measurement (GCM-303)※ 600A/600V Max Input ※ Mini Size ※ High Accuracy ※ MAX Clamp Size: 30mm

Category: LCR Meters
Created on: 30 October 2014

Features: ※ Wide Test Frequency 20Hz ~ 10/5/1MHz ※ 0.1% Basic Accuracy & 6 Digits Measurement Resolution ※ Large LCD Display with Intuitive Interface※ Full Measuring Functions with DUT V/I Monitor※ PASS/FAIL Function ( abs, % or delta) with Judgment Alarm※ DC Resistance Measurement ※ Multiple Step Mode※ Standard RS-232C/GPIB Interface※ Optional DC Bias box

Category: LCR Meters
Created on: 30 October 2014

Features: ※ Test Frequency: 12Hz~200kHz (LCR-821) 12Hz~100kHz (LCR-819/829) 12Hz~10kHz (LCR-817/827) 100Hz~2kHz (LCR-816/826) ※ 0.05%~0.1% Basic Accuracy ※ 100 Sets Memory for Save/Recall of Settings ※ R/Q, C/D, C/R, L/Q, Z/θ, L/R Test Modes ※ Absolute Value,ΔValue, and Δ% Measurement Display ※ 240 x 128 dot Matrix LCD Display ※ Displays Condition and Test Result Simultaneously ※ Standard Interface: RS-232C (LCR-821)/ Handler (LCR-829/827/826)※ Optional Interface: RS-232C (LCR-819/817/816)

Category: LCR Meters
Created on: 30 October 2014

Features: * 20,000/2,000 Counts Dual Display* Test Frequency : 100/120Hz/1/10/100kHz depends on model* Auto LCR Mode for DUT Measuring* 0.2% Basic Accuracy* Measurement Parameter : L,C,R,D,Q,ESR,θ,DCR* Parallel/Series Testing Mode* Sorting Mode for Quality Control* 2Wire or 5Wire Measurement Available* Data Hold and Zero Mode Supported* Max and Min (LCR-916 only)* Auto Range, Auto Backlit* Low Battery Indication* Auto Power off* Data Collection or AC power operation (Optional)

Created on: 30 October 2014

Features: ※ 500VA AC Test Capacity※ 240x64 Ice Blue Dot matrix LCD※ Sweep Function for DUT characteristic analysis※ Insulation resistance measurement up to 50GΩ(GPT-9903/9904)※ Manual/Auto Mode※ Function Key for quick selecation※ High intensity flash for caution & Status indication※ Safety INTERLOCK function※ Zero Crossing Turn-on Operation※ Controllable Ramp-up Time※ True RMS Current Measurement ※ High resolution: 1uA for measuring current, 2V for setting voltage※ PWM amplifier to enhance the power efficiency and reliable testing ※ Max. 100 memory block for test condition (step) setting. And each step can be named individually.※ Remote terminal on the front panel for “start” and “stop” control※ Rear panel output available※ Interface : RS-232C, USB device, Signal I/O and GPIB (optional)

Created on: 30 October 2014

Features: ※ 200VA AC Test Capacity※ 240x64 Ice Blue Dot matrix LCD※ Manual/Auto Mode※ Function Key for quick selecting※ High intensity flash for Caution & Status indication※ Safety INTERLOCK function※ Zero Crossing Turn-on Operation※ Controllable Ramp-up Time※ True RMS Current Measurement ※ High resolution: 1uA for measuring current, 2V for setting voltage※ PWM amplifier to enhance the power efficiency and reliable testing ※ Max. 100 memory block for test condition (step) setting. And each step can be named individually.※ Remote terminal on the front panel for “start” and “stop” control※ Interface : RS-232C, USB device, Signal I/O and GPIB (optional)  

Created on: 30 October 2014

Features: ※ 100VA AC Test Capacity※ 240x48 Ice Blue Dot matrix LCD※ Auto W-I or I-W Mode※ ARC Detection※ True RMS Current Measurement※ Zero Crossing Turn-on Operation※ Safety INTERLOCK function※ PWM amplifier to enhance the power efficiency and reliable testing ※ Automatically Switching Input Source for Universal Input Voltage※ Interface : Remote terminal and Signal I/O

Created on: 30 October 2014

Features: ※ Touch Panel with Color LCD Display※ 9 Different Measurement Network to Simulate the Resistance of Human Body※ 8 Different Types of Leakage current for Medical & General Electrical Equipment※ Various Leakage Current Measuring Mode: DC/AC/AC+DC/AC Peak ※ Upper & Lower Limitation for PASS/FAIL Judgment※ Meter Mode with SELV/CONV Function※ 50 Preset Test Conditions Conform to IEC 60990; 30 Sets Memories for Customer Defined※ Various Standard Interfaces: RS232/GPIB/USB Host & Device/EXT I/O