Features:
4 Independent Isolated Output
0.01% Load and Line Regulation
Low Ripple and Noise
Tracking Operation and Auto Series/Parallel Operation
Output Voltage and Current Setting When Output Disable
Fan Speed Control Circuit to Minimize Fan Noise
Description:
4-channels, 55W D.C. Power Supply
Specification:
|
DC OUTPUT |
|||||||
| Voltage |
|
||||||
| Current |
|
||||||
| Tracking Series Voltage |
|
||||||
| Tracking Parallel Current |
|
||||||
|
CONSTANT VOLTAGE OPERATION (CH1, CH2) |
|||||||
| Line Regulation | < 0.01% + 3mV | ||||||
| Load Regulation | < 0.01% + 3mV (rating current <3A) < 0.02% + 5mV (rating current >3A) |
||||||
| Ripple & Noise | < 1mVrms 5Hz ~ 1MHz | ||||||
| Recovery Time | < 100μS ( 50% Load change, Minimum load 0.5A ) | ||||||
|
CONSTANT CURRENT OPERATION (CH1, CH2) |
|||||||
| Line Regulation | < 0.2% + 3mA | ||||||
| Load Regulation | < 0.2% + 3mA | ||||||
| Ripple Current | < 3mArms | ||||||
|
TRACKING OPERATION (CH1, CH2) |
|||||||
| Tracking Error | < 0.5% + 10mV of CH1 | ||||||
| Series Regulation | < 300mV | ||||||
| Load Regulation | < 0.01% + 3mV | ||||||
| Ripple & Noise | < 2mVrms 5Hz ~ 1MHz | ||||||
|
CH3 : 3V~6V OUTPUT |
|||||||
| Line Regulation | < 5mV | ||||||
| Load Regulation | < 15mV | ||||||
| Ripple & Noise | < 2mVrms 5Hz ~ 1MHz | ||||||
| Current Output | 2.5A | ||||||
|
CH4 : 8V~15V OUTPUT |
|||||||
| Line Regulation | < 5mV | ||||||
| Load Regulation | < 10mV | ||||||
| Ripple & Noise | < 2mVrms 5Hz ~ 1MHz | ||||||
| Recovery Time | 1A | ||||||
|
METER |
|||||||
| Digital |
3 Digits 0.5" LED Display |
||||||
|
INSULATION |
|||||||
| Chassis and Terminal | 20MΩ (> DC 500V) | ||||||
| Chassis and AC Cord | 30MΩ (> DC 500V) | ||||||
| POWER SOURCE | AC 100V/120V/220V( ±10%), 240V(+10% ~ -6%) 50 / 60Hz |
||||||
| ? | ? | ||||||
|
ACCESSORIES |
|||||||
| ? | Instruction manual x 1 Power cord x 1 GTL-105 x 4 or European test lead GTL-203 x 4 |
||||||
| DIMENSIONS & WEIGHT | 255(W) x 145(H) x 265(D)mm, Approx. 6.3kg |
||||||