Bante 903 multi-parameter meter used for measuring the pH,
ORP and Dissolved Oxygen in water.
pH Mode:
  Up to 5 points calibration with auto-buffer recognition.
Up to 5 points calibration with auto-buffer recognition.
  Selectable pH buffer standards, resolution, temperature unit.
Selectable pH buffer standards, resolution, temperature unit.
  Automatically calculates and  displays electrode slope  that
Automatically calculates and  displays electrode slope  that 
helps you decide whether to replace pH electrode.
Dissolved Oxygen Mode:
  1 or    2 points auto-calibration (  100% in saturated air or air-saturated
1 or    2 points auto-calibration (  100% in saturated air or air-saturated 
water, 0% in zero oxygen solution ).
  Manual salinity and barometric pressure compensation.
Manual salinity and barometric pressure compensation.
  Selectable readout in ppm, mg/L or percentage saturation.
Selectable readout in ppm, mg/L or percentage saturation.
General Features:
   Automatic Temperature Compensation (ATC) ensures highly accurate
Automatic Temperature Compensation (ATC) ensures highly accurate
measurements over the entire range.
   Calibration due reminder prompts you to calibrate  the meter regularly.
Calibration due reminder prompts you to calibrate  the meter regularly.
   Automatic endpoint function freezes the stable measured values for
Automatic endpoint function freezes the stable measured values for
easy reading and recording data.
   Manual temperature calibration provides accurate temperature value.
Manual temperature calibration provides accurate temperature value.
   Help message as a operational guide to helps you understand how
Help message as a operational guide to helps you understand how
to use meter.
   Setup menu lets user customizes buffer standards, calibration points,
Setup menu lets user customizes buffer standards, calibration points,
stability conditions, resolution, temperature units, date and time to
meet measurement requirements.
   Reset function can resumes all settings to factory default values.
Reset function can resumes all settings to factory default values.
   Expanded memory stores and recalls up to 500 readings.
Expanded memory stores and recalls up to 500 readings.
   Built-in real-time clock stamps stored data to meets GLP standards.
Built-in real-time clock stamps stored data to meets GLP standards.
   Stored data  can be transferred into  computer via USB communication
Stored data  can be transferred into  computer via USB communication 
interface.
     
     
| Specifications: | ||||||
| Model | Bante903 | |||||
| pH Range | -2.000~20.000pH | |||||
| pH Accuracy | ±0.002pH | |||||
| Resolution | 0.001, 0.01, 0.1pH, Selectable | |||||
| Calibration Points | Up to 5 points | |||||
| Calibration Solutions | USA(pH1.68/4.01/7.00/10.01/12.45), NIST(pH1.68/4.01/6.86/9.18/12.45), DIN(pH1.09/4.65/6.79/9.23/12.75) | |||||
| Temperature Compensation | 0~100°C, 32~212°F, Automatic or Manual | |||||
| mV Range | -1999.9~1999.9mV | |||||
| mV Accuracy | ±0.2mV | |||||
| Resolution | 0.1, 1mV, Selectable | |||||
| Dissolved Oxygen Range | 0.00~20.00mg/L or ppm | |||||
| Resolution | 0.01mg/L | |||||
| Dissolved Oxygen Accuracy | ±0.2mg/L (Calibration and measurement under the conditions of same temperature) | |||||
| % Saturation of Oxygen | 0.0~200.0% | |||||
| Accuracy | ±2.0% | |||||
| Salinity Correction | 0~50g/L | |||||
| Pressure Correction | 60.0~112.5kPa, 450~850mmHg | |||||
| Temperature Compensation | 0~50°C, 32~122°F, Automatic | |||||
| Temperature Range | 0~105°C, 32~221°F | |||||
| Temperature Accuracy | ±0.5°C, ±0.9°F | |||||
| Temperature Calibration | Manual | |||||
| Auto-Off | Manual or Automatic (10, 20, 30 minutes after last key pressed, Selectable) | |||||
| Hold Function | Manual or Automatic | |||||
| Stability Conditions | Low or High, Selectable | |||||
| Calibration due reminder | 0 to 30 days | |||||
| Reset Function | Yes | |||||
| Memory | 500 data sets with Date/Time stamping | |||||
| Output | USB Communication Interface | |||||
| Connector | BNC and 6-pin connector | |||||
| LCD Display | Custom dual-display LCD (130×110mm) | |||||
| Power Requirements | DC5V, using AC adapters, 220VAC/50Hz | |||||
| Dimensions | 210(L)×188(W)×60(H)mm | |||||
| Weight | 1.2kg | |||||
| Order Code and Accessories: | ||||||
| Order Code | Accessories | |||||
| Bante903-UK  |           | |||||
| Bante903-CN |           | |||||

 
 


 
			