Sub Categories
FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment. ● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads. SPECIFICATIONS Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) 0Ω adjustment ˇ Open circuit indication LED will be unlit Low battery indication “ “symbol appears on the display Data hold...
FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads. SPECIFICATIONS Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “ “symbol appears on the display Data hold indication ...
FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified two-wire measuring system.● 0Ω adjustment. ● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads. SPECIFICATIONS Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) 0Ω adjustment ˇ Open circuit indication LED will be unlit Low battery indication “ “symbol...
FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads. SPECIFICATIONS Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “ “symbol appears on the display Data hold ...
FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads. SPECIFICATIONS Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) at 200/2000Ω ±(2%rdg+0.1Ω) at 20Ω Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω 0-200Ω : 0.1Ω 0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “ “symbol appears on the display Data hold ...
FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case. SPECIFICATIONS Test voltage (DC V) 2500V 5000V Measuring ranges 0-100GΩ 0-200GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries
FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case. SPECIFICATIONS Test voltage (DC V) 5000V 10000V Measuring ranges 0-200GΩ 0-400GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries
FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch. SPECIFICATIONS Test voltage (DC V) 0.5kV / 1kV / 2.5kV / 5kV Measuring ranges (Auto-Ranges) 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ Accuracy 0-50GΩ : ±3% rdg 50-250GΩ : ±5% rdg Dimensions 170(L) × 120(W) × 95(D)mm Weight (battery included) Approx. 930g Power source 1.5V(AA) × 8 Safety standard EN 61010-1 EN...



































