Sub Categories
Description: * Clamp Type K Temp. probe, allows for hands-free super-heat (super-cooling) temperature measurement. The useful Temp. probe is ideal for pipe surface temperature, heating, ventilating, air conditioning, engine or cylinder circular tube.* Measurement range : -50 to 350 oC, -58 oF to 662 oF.* Accuracy : 2.5 oC, 4.5 oF.* Spring-loaded jaw for secure grip for pipe size from 3 mm to 48 mm diameter.* Cooperate with any Thermometers built-in Type K thermocouple input .* Cable length : 2 meters coiled cable.
Description: * Real time recorder, save the data into the SD memory card and can be downloaded to the Excel, extra software is no need.* Measurement range : 1125 torr x 1 torr. 1500 mbar x 1 mbar.* Units : torr, mm Hg, mbar, kPa, hPa, inch Hg, psi.* Data hold, Record (Max., Min.).* RS232/USB computer interface.* Heavy duty vacuum sensor used for air, oil gas...* Application : Automobile, Industrial, laboratory, heating, ventilation, medical hospital...* Patented.
Description: * WBGT (wet-bulb globe temperature) was developed as a monitoring basis at US military training camps and became widespread for the use in workplaces and sports situation It is suggested in the international standard ISO 7243, OSHA (US Occupation Safety), Japan Society for Occupational Health and the SMA (Sports Medicine Australia) to establish the permissible heat exposure limits in health, sports or other physical activities.* Measurement : WBGT value (Indoor/Outdoor Wet bulb globe temperature), Black globe temperature, Humidity, Air temperature, Wet bulb temperature, Dew point Temp..* Measurement function : 1. Wet bulb globe temperature (WBGT): Indoor : 0 oC to 59 oC. Outdoor : 0 oC to 56 oC. 2. Black globe Temp (TG) : 0 to 80 oC. 3. Air temperature (TA) : 0 to 50 oC. 4. Wet bulb temperature (WB) : -21.6 oC to 50.0 oC. 5. Humidity : 5 % to 95 % R.H.. 6. Dew point Temp. : -25.3 oC to 48.9 oC.* Unit : oC,oF, Resolution : 0.1 degree.* Adjustable WBGT alarm setting with buzzer sound output.* Control and monitor of physical activity in hot environment to limit the danger of heatrelated injuries.* Globe temperature measurement...
* Dual & differential input, 200 mbar x 0.1 mbar.* Unit : mbar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H2O, meter/H2O, Atmosphere.* Data hold, Memory (Max., Min.).* RS232/USB computer interface.* Application : Industrial, laboratory, schools, heating, ventilation, hospital, medical...* Size : 180 x 72 x 32 mm.
Features: Measuring range: 0 to 100 mbar Resolution: 0.01 mbar Selectable units: differential manometer measures differential pressure in the range from 0 to 100 mbar. The pressure measurement is temperature compensated to obtain accurate measurement values. The measurement values can be displayed inPascal over the entire measurement range. Magnets at the rear of the instrument permit hand free operation. The backlit display allows the measurement values to be easily read, even in unfavourable light conditions. The Testo 510 differential manometer, in combination with a Pitot tube, measures air flow velocity and for accurate measurement values, the air density can be compensated. Features: Measuring range: 0 to 100 mbar Resolution: 0.01 mbar Selectable units: hPa mbar Pa mmH2O mmHg inH2O inHg psi m/s (with optional Pitot tube accessory) fpm (with optional Pitot tube accessory) Temperature and air density compensation Flow velocity measurement with Pitot tube (Pitot tube not included) Display illumination Protective cap for safe storage Dimensions (incl. protective cap): 119mm x 46mm x...
Description: MANOMETER, 2000 mbar, differential input Model : LUT0068 PM-9100 * Dual & differential input, 2000 mbar x 1 mbar. * mbar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H20, meter/H2O, Atmosphere. * Data hold, Memory(Max.,Min.), RS232. * Application : Industrial, laboratory, schools,heating, ventilation, hospital, medical... * Size : 180 x 72 x 32 mm.
differential pressure meter, 0 to 2000 hPa, incl. battery and calibration protocol 8 switchable units of pressure: kPa, hPa, Pa, mm H2O, mmHg, psi, inch H2O, inch Hg Integrated density compensation Display illumination Hold-/max-/min function Printout of measurement values incl. date/time and min/max values Storage temperature -10 to +70 °C Operating temperature 0 to +60 °C Battery type 9V block battery, 6F22 Battery life 120 h Weight 300 g Dimensions 202 x 57 x 42 mm Material/Housing ABS Probe type Pressure sensor integrated Meas. Range 0 to +2000 hPa Accuracy 0.5% of fsv Resolution 1 hPa
• Gage, Absolute and Differential Pressure Models • MIN/MAX, Hold and Averaging Modes (HHP242 only) • 8 User Selectable Engineering Units • User Activated Back Light • Auto Shutoff After 20 Minutes of Keypad Inactivity • 0 to 100% Horizontal Bargraph This delivers precision pressure measurement for field, plant or lab use. Two models are available. The low cost HHP241 with 0.25% FS accuracy, including temperature effects, or the HHP242 with 0.1% FS accuracy. The HHP242 series also have MIN/MAX, Hold and Display Averaging Modes. Both units are available in differential, gage or absolute pressure ranges. SPECIFICATIONS Accuracy: HHP241V2:±0.25% FS HHP242V2:±0.1% FS Storage Temperature:-10 to 50°C (14 to 122°F) Operating Temperature:-40 to 60°C (-40 to 140°F) Temperature Effects:No temperature effect over the entire operating range Engineering Units:8 user selectable (InH2O, mmH2O, mmHg, InHg, kPa,mBar, bar and psi) Proof Pressure:3x full scale or 14 bar (200 psi) whichever is less (high side only on...