Sub Categories
HIGH ACCURACY AND RESOLUTION UP TO 0.001mm or 0.0001 inch MEASURING ULTRA THIN SAMPLE AS LOW AS 0.15mm or 0.006 inch DISPLAY UNITS : IMPERIAL and METRIC AUTOMATIC SELF CALIBRATION COUPLANT INDICATOR AUTOMATIC POWER OFF DEVICE HIGH-LOW LIMIT ALARM LCD BRIGHTNESS ADJUST LOW BATTERY INDICTOR TECHNICAL SPECIFICATIONS: Measuring Range (for steel) Interface-Echo Mode: (I-E or Standard Mode) 1.50mm – 20.0mm (0.059in – 0.787 in) Echo-Echo Mode: (E-E or High Precision Mode) 0.15mm – 10.0mm (0.006in – 0.394in) Measuring Accuracy ±0.005mm or 0.0002 inch (if thickness < 3mm) ±0.05mm or 0.002 inch (if thickness < 20mm) Display Resolution mm : 0.1 / 0.01 / 0.001 inch : 0.01 / 0.001 / 0.0001 Sound Velocity Range 1000 to 9999 m/sec (0.0394 – 0.3936 inch/ms) Measuring Refresh Frequency 4Hz in normal mode, up to 25Hz Memory Capacity 500 test values Multiple Calibrations One point or Two Point Display LCD 42×57mm LCD size with EI backlight and adjustable contrast, font size up to 13.75mm (0.54 inch) Power...
HIGH ACCURACY AND RESOLUTION UP TO 0.001mm or 0.0001 inch MEASURING ULTRA THIN SAMPLE AS LOW AS 0.15mm or 0.006 inch DISPLAY UNITS : IMPERIAL and METRIC AUTOMATIC SELF CALIBRATION COUPLANT INDICATOR AUTOMATIC POWER OFF DEVICE HIGH-LOW LIMIT ALARM LCD BRIGHTNESS ADJUST LOW BATTERY INDICATOR STANDARD DELIVERY: Main Processor with Calibration block (4.00 mm) Precision Probe (D11R) with Replaceable Delay Tip Coupling Paste Operation Manual Consumer-Type 2 AA Type Alkaline Battery (3 Volt) Carrying Case
Product Description Auto Calibration to assure the accuracy Auto linear compensation: this advanced software program enhances the precision by correcting the non-linear accuracy of transducer Use ▲ and ▼ keys to make a quick adjustment for the sound velocity/thickness and a quick recall to the stored data Coupling status indication: Observing the coupling icon to learn if the coupling is accomplished or not 10 thickness measurement storage and recall function available, which facilitated the height work or working in wild area Sound velocity measurement: with a given thickness by a sample hardware to measure the sound velocity, which avoid the further conversion or consultation of the table 12 sound velocity for different material which also adjustable Low battery indication Auto power off mode designed to conserve battery life More than 10000 times long life keys The unit has a special memory that retains all of its setting even when the power is off
Specifications H cross hatch cutter is applicable to determine the adhesion of organic coatings by cross-hatching. This instrument is designed for assessing the resistance of paint or related coatings to separation from substrates when a right-angle lattice oattern is cut into the coating, penetrating through to the substrate. The Cross Hatch Cutters conform with the requirements of :BS 3900 E6;BS/EN ISO 2409;ASTM D 3359;GB/T 9286, ,it is economy. Main Technical Parameters: 1.Six working side blades:When the blade edge is not sharp enough, users can loosen the boat type nut and top thrust screw to change blade. 2.Multi-cutting blades spacing:1mm/2mm/3mm 3.The number of square:25squares/100squares
Analysis for Single Phase and Balanced 3 phase system True RMS Value (V and I) Active Power (K,KW,MW,GW) Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR) Power Factor (PF), Phase Angle( Φ ) Energy (WH,KWH,KVARH,PFH) Programmable PT(1 to 3000)Ratios Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W,KW,MW) with programmable Period Harmonic Analysis (V and I) to 50th Order Display of 25 Harmonics in one screen Optical Isolated RS-232C Interface Smart Datalogging to save Battery Datalogging of 32,64,128 or 256 points/cycles Analysis of Total Harmonic Distortion (%THD-F) Graphic Phasor Diagram Capture 128 Transient Events (Time+Cycles+Faults) with Programmable Threshold(%),also can be reviewed in LCD 50000 Records with Programmable Interval (1 to 6000 seconds) Real-time Output of Waveform, Power Parameters and Harmonics at Command Large Dot Matrix LCD Display with Backlight Power for Long-term Monitoring Built -in Calendar Clock for Data Logging General Specification: Conductor Size 55mm(approx.), 64*24mm(bus bar) Battery Type Two...
Functionality and Safety Packed into a Handheld Unit Use as a single-phase power meter Measure phase on a single-phase line Simple checking of three-phase lines Check power supply fluctuations For harmonic suppression External output of data to PC Printer output to 9442 (optional)
The clamp power analyser is a very economical solution for the analysis of single phase or balanced 3 phase systems with voltages to 600VAC and current to 2000 amps. The product uses the same SD card logging. Readings are logged from every 2 second to 7200 seconds as instantaneous values. It also captures 3 types of transient events with programmable threshold. The display is graphical dot matrix and has many graphic formats including waveform on voltage and current - phasor diagram and others. Measures ACV, ACA, KW, KVA, KVAR, PF Measures KWH, KVAH, KVARH, PFH Frequency, harmonics to 50th Type K thermocouple input 0.1 resolution to 199.9C then 1C to 1200C SD card logging Cables to 57mm 10amps to 2000amps autorange Record graphic displays to memory as .bmp files
TEN810-Datalogging Large Wall Display Temperature /Humidity Monitor with 95dB Sound Alarm/Controller
Complete environmental monitor and alarm - Wall-Mounted LED type, easy reading - Alarm set for Hi and Low limit-Temperature and Humidity - Data Logging Capacity 30,000 records - LED displays real time data - USB interface- XL Display: 260 x 178 x 47mm- High Accuracy and high sensitivity