Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 2.3 to 700 Nm³/h Pipe diameter: DN 50 (for 2" pipes) Weight: 3.8 kg Max. display value norm volume flow: 840 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 1.3 to 410 Nm³/h Pipe diameter: DN 40 (for 1 1/2" pipes) Weight: 3.0 kg Max. display value norm volume flow: 492 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 0.75 to 225 Nm³/h Pipe diameter: DN 25 (for 1" pipes) Weight: 1.1 kg Max. display value norm volume flow: 270 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters
Created on: 21 February 2014

Leakage detection, compressed air consumption meaurement Consumption cost allocation Peakload management Measuring range: 0.25 to 75 Nm³/h Pipe diameter: DN 15 (for 1/2" pipes) Weight: 0.9 kg Max. display value norm volume flow: 90 Nm³/h Min./max. monitoring Control of consumption-dependent maintenance strategies Automatic, exact compressed air dosage

Category: Transmitters
Created on: 21 February 2014

Measurement of differential pressure; optional: humidity and temperature Automatic zero-point adjustment guarantees high, temperature-independent accuracy and long-term stability Low measurement range up to 10 Pa ensures highest precision at lowest pressures Flat housing allows flush surface integration in the cleanroom wall Display with multi-language operating menu and optical alarm display Preparation for external humidity/ temperature probe Testo 6610 Piezoresistive sensor 0.1 Pa Resolution 0.1 percent RH Humidity 0.01° C Temperature Protection class: IP 65 Operation temperature: -5 to 50° C Storage temperature: -20 to 60° C Process temperature: -20 to 65° C Measures 161 mm length, by 78 mm width, by 396 mm height

Category: Transmitters
Created on: 21 February 2014

Automatic zero-point adjustment guarantees high, temperature-independent accuracy and long-term stability Low measurement range up to 10 Pa ensures highest precision at lowest pressures Flat housing allows flush surface integration in the cleanroom wall Display with multi-language operating menu and optical alarm display Differential pressure: scalable +/-50 percent of measuring range final value; freely scalable within measuring range Measuring cycle: 1/sec Resolution: 12 bit Maximum load: 500 ohms Front plate stainless steel, housing plastic material 3-line LCD with multi-language operating menu Operation temperature: -5 to 50° C Storage temperature: -20 to 60° C Process temperature: -20 to 65° C Measures 161 mm length, by 78 mm width, by 396 mm height Preparation for external humidity/temperature probe Testo 6610 Piezoresistive sensor

Category: Transmitters
Created on: 21 February 2014

Measurement of differential pressure, flow velocity and volume flow Automatic zero-point adjustment guarantees high, temperature-independent accuracy and long-term stability Display with multi-language operating menu and optical alarm display Ethernet, relay and analog outputs allow optimum integration into individual automation systems Self-monitoring of the transmitter and early warning function guarantee high system availability 4 relay outputs, limit value monitoring Cable entry NPT 1/2" Operating temperature: -5 to 50 ° C Storage temperature: -20 to 60 ° C Process temperature: -20 to 65 ° C Measures 162 mm length by 77 mm width by 122 mm height Piezoresistive sensor Measuring cycle: 1/sec Maximum load: 500 ohms Differential pressure: mbar/min/max Protection class: IP 65

Category: Transmitters
Created on: 21 February 2014

Measurement of differential pressure in the measuring range of 0 to 100 Pa Accuracy +/-1.2 percent of Measuring range: + intrinsic error of 0.3 Pa - valid for zeroing cycle of 60 sec/nominal temperature 22 ° C Freely scalable: +/-50 percent of measuring range final value and free scalability within the measuring range Piezoresistive sensor Automatic zero-point adjustment: via magnetic valve Protection class: IP65 only when the transmitter is wired and/or sealing plugs are in use Output type: 0 to 5V (3 or 4-wire) Measuring rate: 1/s Resolution: 12 bit Maximum load: 500 ohms Humidity (sensor): 0 to 90 percent rF Temperature (sensor): -5 to 50 ° C Storage temperature: -40 to 80 ° C