Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 14 February 2014

For the complete solution to HVAC troubleshooting, the extra value-packed 116/62 MAX+ HVAC Technician’s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

Created on: 14 February 2014

Current Range: 0.1 to 100A DC or 0.1 to 70A AC Basic Accuracy (DC to 1kHz): 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading Output Signal: 10A range: 100mV/A | 100A range: 10mV/A Bandwidth: 1Hz to 20kHz Working Voltage: 600V AC rms Maximum Conductor Size: 1.8 mm (.46 inch) diameter Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Created on: 14 February 2014

Current Range: 1 to 600 A DC or AC Peak Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A) Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A Frequency Range: 40 Hz to 400 Hz Working Voltage: 600 V AC rms Maximum Conductor Diameter: 34 mm (1.34 inch) Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Created on: 14 February 2014

Current Range: 100mA to 1000 Arms Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output Bandwidth: 5Hz to 100kHz Working Voltage: 600V AC rms Maximum Conductor Size: 54 mm (2.13 inch) diameter Safety Rating: 600V rms. CAT III per IEC 1010-02-032

Created on: 14 February 2014

Battery-powered dual Hall-effect, clamp-on probe measures dc current from 1-1000A; ac current from 1-600A ac rms Measures ac and dc current down to 1 amp with specified accuracy and is useable to 0.5A Output is 1 mV per amp dc or ac Jaws accept conductor size of 1 X 750 MCM ( 30 mm/1.18 in. diameter) or 2 X 500 MCM (2 X 25 mm/.98 in.) AC and DC accuracy: ± (2.0% of reading + 0.5A)

Created on: 14 February 2014

i1010 1-600A AC rms, 1-1000A DC Current Clamp Zippered vinyl carry case with moveable divider

Created on: 14 February 2014

Companion to a DMM to measure up to 200 A AC 1mA per Amp output guarantees easy reading on you meter Take accurate current readings without breaking the circuit Max. conductor Ø 20 mm CAT III 600V safety rating

Created on: 14 February 2014

Three ranges: 20A, 200 A & 2000 A, 1 mV, 10 mV & 100 mV/A output Ideal for current measurement on thick and hard to reach conductors without breaking the circuit Maximum conductor diameter 178 mm CAT III 600V safety rating