Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● The leads are supplied as standard accessories for    simplified two-wire measuring system.● 0Ω adjustment. ● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) 0Ω adjustment ˇ Open circuit indication LED will be unlit Low battery indication “  “symbol appears on the display Data hold...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● The leads are supplied as standard accessories for    simplified two-wire measuring system.● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “  “symbol appears on the display Data hold indication ...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● The leads are supplied as standard accessories for    simplified two-wire measuring system.● 0Ω adjustment. ● Battery operated.● Data hold function.● Low battery indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) 0Ω adjustment ˇ Open circuit indication LED will be unlit Low battery indication “   “symbol...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without    tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified    two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “  “symbol appears on the display Data hold ...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without    tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified    two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) at 200/2000Ω ±(2%rdg+0.1Ω) at 20Ω Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “   “symbol appears on the display Data hold ...

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.     SPECIFICATIONS       Test voltage (DC V) 2500V  5000V Measuring ranges 0-100GΩ 0-200GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● High quality Taut Band movement.● Two insulation test voltages.● Insulation resistance, auto ranging on all ranges.● Low Battery LED indication.● Beeper warning of external voltage.● Fully protected : crow bar.● Housed in carry case.     SPECIFICATIONS       Test voltage (DC V) 5000V 10000V Measuring ranges 0-200GΩ 0-400GΩ Accuracy ±5% of full scale Live warning >500V AC Operating-temperature 0°C to 40°C Operating-humidity 85% Max. relative humidity Dimensions 330(L) × 260(W) × 160(D) mm Weight (battery included) Approx. 3500g Power source 1.5V “C”× 8 Alkaline batteries

Created on: 18 February 2014

FEATURES ● Microprocessor-controlled.● Four insulation test voltages.● Insulation resistance; auto ranging on all ranges.● Bargraph indicates test voltage; rise and decay can be observed    during tests.● Visual and audible warning if external voltage is present.● EnerSave™ feature to extend battery life.● 2 Lines × 16 characters large LCD.● Low battery consumption.● Low battery indicator.● Overload protection.● Auto-off.● Show test time duration (up to 99.9s) for easy comparison.● EEPROM calibration.● Built-in carry case and test leads in separate pouch.     SPECIFICATIONS             Test voltage (DC V) 0.5kV /   1kV     /   2.5kV   /   5kV Measuring ranges (Auto-Ranges) 0-25GΩ / 0-50GΩ / 0-125GΩ / 0-250GΩ Accuracy 0-50GΩ : ±3% rdg 50-250GΩ : ±5% rdg Dimensions 170(L) × 120(W) × 95(D)mm Weight (battery included) Approx. 930g Power source 1.5V(AA) × 8 Safety standard EN 61010-1 EN...