Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 28 October 2014

The 701944 is an oscilloscope passive probe supporting up to 1000Vrms, 400MHz bandwidth, and 100:1 attenuation ratio. The probe length is 1.2 meters, with a 50MΩ input resistance. This probe is well suited for high voltage, higher bandwidth single ended voltage measurements at an affordable cost. It is compatible with Yokogawa oscilloscope models DLM2000, DLM4000, DL/DLM6000, DL9000, SB5000 and DL1700. See also 701945 for the 250MHz bandwidth version of this same probe.

Created on: 28 October 2014

Passive Probe, 1000Vrms, 250MHz, 100:1, 50MΩ, 3.0m, 'Mini' with extra-long 3m lead.  Compatible with DL1700, DLM2000, DLM4000, DL/DLM6000, DL9000 and SB5000.  See also 701944 for 400 MHz version of this same probe.

Created on: 28 October 2014

Passive Probe, 3540Vp-CAT I, 1000Vp-CAT II, 200MHz, 100:1, 100MΩ, 1.5m, 'Isolated Probe'  'Iso-Probe'.  For use with 701250, 701251, 701260, 701280, 701281, 720210 isolated-input modules ONLY.  For use with DL850 series, DL750/DL750P, SL1400, and SL1000.  Not for use with CAT III or CAT IV measurements

Created on: 28 October 2014

Use this 10:1 active probe with the DL6054,  DLM6054, DL9040/DL9040L , DL9505L/DL9705L,  DLM2052/DLM2054 series to realize system measurements up to 500 MHz BW.

Created on: 28 October 2014

Use this 10:1 active probe with the DL6104, DLM6104, DL9140/DL9140L , DL9510L/DL9710L, SB5000 series to realize system measurements up to 1.0 GHz BW.

Created on: 28 October 2014

Use this 10:1 active probe with the DL6154, DL9240 series to realize system measurements up to 1.5 GHz BW.

Created on: 28 October 2014

The PBL5000 low-capacitance "transmission line" probe (passive) features both 10:1 and 20:1 attenuation.This probe requires a 50 Ω scope/termination and can be used with any oscillscope with a BNC input. The change in attenuation is realized by changing resistance on the tip of the probe; Can also be used with DC Block 701975. For use with a scope which does not have a built-in 50 Ω termination, please purchase a 700976 50 Ω external (BNC) pass-thru terminator.

Created on: 28 October 2014

Passive Probe, 600Vpeak, 6MHz/10MHz, 1:1, 10:1, 1MΩ/10MΩ, 1.5m '600V Non-Isolated' Typically used for non-isolated ScopeCorder module 701255 on the Dl850/DL850V/DL750/DL750P/SL1400/SL1000.