SEW-Taiwan
SEW New
Sub Categories
FEATURES ● Designed for RJ45/RJ11 modular cables, 10/100 base-T cable and Token Ring cable.● The LAN cable tester can verify cable continuity, open, short circuit and miss-wired. ● The remote receiving unit is available for installed cables far away either on the wall plates or on the patch panels.● Auto and manual scan functions.● Ground wire test. ● Lock status function.● Buzzer sound warning for wire status.● Display : LED indication for wire status. SPECIFICATIONS Display LED Operating temperature 0°C ~ 40°C Dimensions Master unit 132(L) × 55(W) × 39(D)mm Remote receiving unit 74(L) × 30(W) × 25(D)mm Weight (battery included) Master unit : 148 g Remote receiving unit : 33g Power source 9V × 1 Safety standard EN 61326-1
FEATURES Lan Cable Tester ● Designed for RJ45/RJ11 modular cables, 10/100 base-T cable and Token Ring cable etc.● The LAN cable tester can verify cable continuity, open, circuit and miss-wired. ● The remote receiving unit is available for installed cables far away either on the wall plates or on the patch panels.● Auto and manual scan function.● Ground wire test.● Display : LED indication for wire status. Digital Multimeter ● 4000 counts LCD.● Full automatic measurement. Voltage measurement. Resistor measurement.● Range change function.● Select function.● Data Hold function.● Continuity check.● Diode measurement.● Low battery indication.● Input impedance:10MΩ. SPECIFICATIONS AC Voltage Range Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+5dgt) 4V 1mV 40V 10mV 400V 100mV 750V 1V DC Voltage ...
FEATURES Cable Tracer ● Trace wires or cables.● Volume control.● Tip & Ring identification.● 2 bi-colored LEDs ( Line 1 & Line 2).● Tone speed selection : Fast & Slow.● A phone jack is designed for headset or handset. (Amplifier probe) Digital Multimeter ● 4000 counts.● ACV, DCV.● Ohm, Diode, & Continuity testing.● Auto-range.● Data hold.● Low battery indication.● Select function.● Auto-off. SPECIFICATIONS AC Voltage Range Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+5dgt) 4V 1mV 40V 10mV 400V 100mV 750V 1V DC Voltage Range Resolution Accuracy 400mV 0.1mV ±(0.5%rdg+3dgt) 4V 1mV 40V 10mV 400V 100mV 1000V 1V Resistance Range Resolution Accuracy ...
FEATURES ● Non-contact detector clips. No metal contact points to advocate greater safety.● Two functions in one unit : open phase and phase sequence detection.● Designed for checking a wider range of 3-phase power sources.● LED display lights with buzzer indicator. ● Brightness button feature for better visibility in dimly lit areas or sunlight.● Magnetic mounting feature. SPECIFICATIONS Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 7V ± 0.2 or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 128(L) × 72(W) × 44(D)mm Weight (battery included) Approx. 380g Power source 9V (6LF22) × 1 Safety standard EN 61010-1...
FEATURES ● The 890 PR is a Non-Contact phase detector with flashing LEDs and a beeping buzzer to show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and phase sequence detection.● Convenient brightness switch to make the indication visible in dim areas or sunlight.● Back cover magnet attaches the instrument to the AC distribution panel offer easy measurement.● 3-Phase AC 75 to 1000V is fitted for detection.● Detect frequency range is from 45 to 65Hz. SPECIFICATIONS Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 4.6±0.1V or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 118(L) × 69(W) × 38(D)mm Weight (battery included) Approx. 370g ...
FEATURES ● The 4156 PR is used to identify the leads of a diconnected motor so that when the motor is in true phase sequence, it will run in the desired direction. SPECIFICATIONS Measuring ranges 0~200kΩ Test leads AL-34 length : 50cm Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1280g Power source 1.5V (AA) × 2 Safety standard EN 61010-1 EN 61326-1
FEATURES ● Indicates phase rotation. ● Indicates phase presence.● Indicates motor rotation/wiring.● Indicates battery status.● Phase rotation and motor rotation indication works from as low as 1Vac.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 100 Vac. ● Very low consumption.● Fused. ● Lightweight, robust and compact.● Works from 2 Hz to 400 Hz Sine. SPECIFICATIONS Phase Presence Nominal Voltage for Phase Presence Indication (The voltage required for the neon Lamps L1, L2, L3 to light up). From To Freq 100Vac 500Vac 10-400Hz Determination of Phase Rotation Field Direction From To Freq 1Vac 500Vac 2-400Hz Determination of Motor Connections (requires > 1/2 turn of the shaft) From To Freq 1Vac 500Vac 2-400Hz Maximum Current Consumption 18mA Over Voltage CLASS III 500V Over Load between all terminals 500V Battery OK goes off when battery voltage < 6.5 Vdc Dimensions ...
FEATURES ● Indicates phase rotation. ● Indicates phase presence.● No battery required.● Phase rotation phase presence indicated on large liquid crystal display.● Small, rugged enclosure.● Color coded test leads.● Phase presence indication from as low as 40Vac to as high as 500Vac.● Fused.● Lightweight, robust and compact.● EN 61010-1 CAT III 500V EN 61010-2-032 SPECIFICATIONS ELECTRICAL Determination of the Phase Presence Nominal Voltage for Phase Presence Indication (the voltage required for the LCD L1, L2, L3 indicators to come on) From 40Vac to 500Vac. Frequency range From 15Hz to 400Hz. Determination of the Phases Rotary Field Direction: Direction Indication by LCD Display(the voltage required to have the LCD Direction Arrows to indicates and the L1 L2 L3 or L3 L2 L1 indicators to show) From 40 to 500Vac. Frequency range From 15 Hz to 400Hz Protection Over load 700V(between...