SEW-Taiwan

SEW New

  • Filter
Created on: 20 February 2014

FEATURES ● 3000 counts with a maximum display of 2999.● Angled display design helps the user to identify the     reading of value easier.● Auto scanning function for AC/DC voltage, and current.● Auto ranging.● Range change function.● Continuity check.● Diode & Capacitance measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.     SPECIFICATIONS       DC Voltage         Ranges Resolution Accuracy Input protection 300.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 3.000V 1mV 30.00V 10mV 300.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage         Ranges Resolution Accuracy Input protection 300.0mV 100μV ±(1%rdg+5dgt) 800V...

Created on: 20 February 2014

FEATURES ● 4000 counts LCD with a maximum display of 3999.● Angled display design helps the user to identify the reading of value   easier.● Auto ranging designed.● Range change function.● Continuity check.● Diode measurement.● Data hold function.● Low battery indication.● Over range indication.● Fuse protection.● Special hook design used to hang the meter for ease of use.     SPECIFICATIONS       DC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(0.5%rdg+3dgt) 1000V DC 4.000V 1mV 40.00V 10mV 400.0V 100mV 1000V 1V ․Input impedance : 10MΩ AC Voltage         Ranges Resolution Accuracy Input protection 400.0mV 100μV ±(1%rdg+5dgt) 800V AC 4.000V 1mV 40.00V 10mV 400.0V 100mV 750V 1V ․Input impedance : 10MΩ DC...

Created on: 20 February 2014

FEATURES ● 3½ digit, high contrast LCD, with a maximum display of 1999.● Automatic polarity indication, zero adjust.● Low battery (BAT) indication.● Over range indication: highest digit of (1) or (-1). ANALOG DISPLAY ● Large 90º wide and 84mm long mirror scale. (adapted to digital,   analog maximum indication 2400).● Peak hold mode.● Shock and vibration resistant TAUT BAND movement.● Switch selection normal (left hand side) zero or center (galvo-mode)   zero. Polarity + or -, pointer turn to right hand side, avoid opposite   direction.● Centre zero and ohm zero : automatic● Dimensions: 167(L) × 102(W) × 39(D)mm     SPECIFICATIONS       DC...

Created on: 20 February 2014

FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS         Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...

Created on: 20 February 2014

FEATURES ● Microprocessor-controlled.● Four terminal measurement.● Measures down to 100μΩ.● 5 Ranges from 200.0mΩ to 2000Ω.● Maximum resolution of 100μΩ.● Three test currents with over-temperature protection.● Protection against inadvertent connection to over voltage.● Large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave inside.● EnerSave Auto hold.● EnerSave Auto off.● Lightweight, robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS         Measuring ranges 0-200.0mΩ in steps of 100μΩ 0-2000mΩ in steps of 1mΩ 0-20.00Ω in steps of 10mΩ 0-200.0Ω in steps of 100mΩ 0-2000Ω in steps of 1Ω Accuracy ±0.5% of reading ±2 digits over the operating temperature range, -15ºC to +55ºC, with the supplied test leads Test current 1mA=>2000Ω range 10mA=>200 / 20Ω ranges 100mA=>2000m / 200mΩ ranges Test current accuracy ±0.1% Protection fuses Mains = 0.5A,...

Created on: 20 February 2014

FEATURES ● Microprocessor-controlled.● Measure down to 1μΩ.● 6 ranges from 2.000mΩ to 200.0Ω.● Maximum resolution of 1μΩ.● Three test currents with over-temperature protection.● Four terminal measurement.● Protection against inadvertent connection to over-    voltage. (crow bars for current and voltage)● Clear & large LCD.● Potential lead resistance and current lead resistance checks.● "Full-featured” EnerSave™ Inside.● EnerSave™ Auto-hold.● EnerSave™ Auto-off.● Rechargeable battery operated● Robust & compact.● Indicators show if reading may be invalid (RP, RC, and     temperature).● "O-Ring” sealed case.     SPECIFICATIONS       Low resistance ranges / resolution 0-2.000mΩ / 1μΩ 0-20.00mΩ / 10μΩ 0-200.0mΩ / 100μΩ 0-2.000Ω / 1mΩ 0-20.00Ω / 10mΩ 0-200.0Ω / 100mΩ Accuracy 0-2.000mΩ : ±(5%rdg+5dgt) 0-20.00mΩ : ±(4%rdg+4dgt) 0-200.0mΩ : ±(4%rdg+4dgt) 0-2.000Ω : ±(3%rdg+4dgt) 0-20.00Ω : ±(2%rdg+4dgt) 0-200.0Ω : ±(2%rdg+4dgt) Test current (dc) 2.000mΩ to 200.0mΩ :...

Created on: 20 February 2014

FEATURES ● AC Voltage Input/output range:   100~240 Vac● Frequency:   50~60Hz● Current:   10A     SPECIFICATIONS Current capacity 10Aac(125V) Withstand voltage 2210Vac for 1 minute between the electric circuit and the case ACV Input/Output 100~240V 50/60Hz Dimensions 170(L) x 165(W) x 92(D)mm Weight Approx. 820g Meets EN 61010-1 CAT.Ⅲ 250V

Created on: 20 February 2014

FEATURES ● High quality Taut Band movement.● Four functions : DC current, AC current, AC+DC current, and ACV   measurement.● Three input resistance ranges: 1kΩ,1.5kΩ and 2kΩ.● 200uA full scale value.● ±2.5% full scale value accuracy.● Built-in overload protection circuit.● Robust, compact and easy to carry.     SPECIFICATIONS            Ranges    DC Current : 0.1-1-10mA AC Current : 0.1-1-10mA AC+DC current : 0.1-1-10mA AC Voltage : 150-300V (50/60Hz) Accuracy : ±2.5% of full scale Input impedance Current Ranges : 1kΩ, 1.5kΩ and 2kΩ Voltage Ranges : 150V/500kΩ 300V/1MΩ Working frequency 20Hz ~5kHz Overload protection Withstands 30mA AC for 10 minutes for each current measuring range Operating temperature 0ºC ~ 40ºC Operating humidity Max. 80% R.H. Dimensions 210(L) × 210(W) × 100(D)mm Weight (battery included) Approx. 1395g Power source 1.5V (AA) × 8 Safety standard EN 61010-1 CAT III 600V EN 61326-1