FEATURES ● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 210mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● BS 16 edition     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 250V / 500V 1000V Measuring ranges 0-200MΩ  0-2000MΩ Resolution 1 count / 100kΩ 1 count / 1MΩ Accuracy ±(1.5%rdg+5dgt) ±(3%rdg+3dgt) (under 1GΩ/2000MΩ) ±(5%rdg+3dgt) (under 2GΩ/2000MΩ) Output voltage on open circuit Rated test Voltage +10% Output current 1mA DC Power consumption 250mA  Continuity     Measuring range 0-20Ω    0-2kΩ Accuracy ±(1.5%rdg+5dgt) ±(1.5%rdg+3dgt) Resolution 0.01Ω      1Ω Buzzer sound...

Created on: 19 February 2014

FEATURES ● Microprocessor-controlled.● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-2MΩ / 0-20MΩ / 0-200MΩ / 0-2000MΩ Output voltage open circuit +10% Accuracy 0-2MΩ : ±(5%rdg+5dgt) 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Resolution 0-2MΩ : 1kΩ 0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-600V  Resolution 1V Line frequency range 40-120 Hz Accuracy ±(1.5%rdg+3dgt) Current for...

Created on: 19 February 2014

FEATURES ● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm ( 2.677” × 1.338” ) large LCD display.● LCD backlight display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function.● BS 16 edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20MΩ / 0-200MΩ / 0-2000MΩ Output voltage open circuit +10% Accuracy 0-20MΩ : ±(1.5%rdg+5dgt) 0-200MΩ : ±(2.5%rdg+3dgt) 0-2000MΩ : ±(5%rdg+5dgt) Resolution 0-20MΩ : 10kΩ 0-200MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-500V Resolution 1V Line frequency range 40-120 Hz Accuracy ±(1.5%rdg+3dgt) Current for continuity     Measuring range 0-200Ω ...

Created on: 19 February 2014

FEATURES ● Microprocessor-controlled.● 68 x 34mm large LCD display.● 3½ digital LCD (2000 counts) a LCD indicated instrument for    insulation(MΩ), continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● Auto ranging.● Auto power off function.● Auto data hold function.● Rel function (ohm only)● Continuity buzzer.● External AC voltage warning.● Automatic circuit discharge.● BS 16th edition.     SPECIFICATIONS   Insulation Resistance     Test voltage 250V / 500V / 1000V Measuring ranges (Auto ranging) 0-20.00MΩ 0-200.0MΩ 0-2000MΩ Output voltage open circuit Rated test voltage +10% Accuracy 20MΩ : ±(1.5%rdg+2dgt) 200MΩ : ±(2.5%rdg+2dgt) 2000MΩ : ±(5%rdg+3dgt) Resolution 0-20.00MΩ : 10kΩ 0-200.0MΩ : 100kΩ 0-2000MΩ : 1MΩ Output current 1mA DC AC Voltage     Range 0-500V Resolution 1V Accuracy ±(1.5%rdg+3dgt) Continuity     Ranges 20Ω / 200Ω / 2000Ω Resolution 0-20Ω : 0.01Ω...

Created on: 19 February 2014

FEATURES ● High quality Taut Band movement.● Battery operated.● Solid state circuitry.● Battery check feature.● Automatic circuit discharge.● Three insulation test voltages.● Color-coded scale.● AC voltage measurement.● Fuse protected.   SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 50V   /   125V   /   250V Measuring ranges 0-20MΩ / 0-50MΩ / 0-100MΩ Output voltage on open circuit Rated test voltage +10% Accuracy ±5% of indicated value Short circuit terminal current 2mA DC Power consumption 190mA Continuity     Measuring range 0-50Ω & ∞ Accuracy ± 5% of scale length Open circuit terminal voltage 445mV DC Approx. Short circuit terminal current 145mA DC Approx. Power consumption 200mA AC Voltage     Range 0-600V AC Accuracy ± 2.5% of full scale Line frequency range 40-1kHz General     Dimensions 170(L) × 165(W) × 92(D) mm Weight ...

Created on: 19 February 2014

FEATURES ● High quality Taut Band movement.● Measures insulation(MΩ) and AC voltage.● LED indiction for testing insulation.● Highly efficiency and accurate DC-DC converter.● Battery check function.● Compact and lightweight.● AC voltage measurement can be made without depressing the test    button.     SPECIFICATIONS   Insulation Resistance     Test voltage (DC V) 100V Output voltage on open circuit Rated test voltage +10% Measuring ranges 0-200MΩ Mid-scale value 5MΩ Accuracy 0.2-100MΩ : ± 5% rdg 0.7% of scale length at other ranges Short circuit current 1mA DC AC Voltage     Range 0-500V Accuracy ± 2.5% of full scale General     Operating temperature & humidity 0°C ~ 40°C relative humidity up to 85% Storage temperature & humidity -10°C ~ 50°C relative humidity up to 85% Dimensions 175(L) × 85(W) × 75(D) mm Weight (battery included) Approx. 510g Power source 1.5V (AA) × 4 Safety standard EN...

Created on: 19 February 2014

FEATURES ● High contrast OLED display● Designed for viewing in the dark, for mining industry.● Wide viewing angle.● Smart microprocessor-controlled.● 2 x 16 characters, large, High Contrast, Intelligent OLED Display.● Automatically calculates Delectric Absorbtion Ration (DAR).● Automatically calculates Polarization Index (PI).● Insulation resistance; Auto-ranging on all ranges.● Ener-Save● Bar graph indicates test voltage. Rise and decay can be obeserved.● External voltage presence warning (>500Vac or Vdc)● Overload protection● Low battery indicator (real time battery voltage mearsurement)● Measures insulation time duration of the test● Better than 10% accuracy on all ranges● Auto-off   SPECIFICATIONS   Test voltage From 500Vdc to 10kVdc Adjustable in 500V Steps Preset buttons 1kV, 2.5kV, 5kV, 10kV Measuring range 800kΩ-500GΩ (auto-ranging) Accuracy ±5% ± 2 digits Output power limit 1W Voltage regulation Selected Voltage +20%-5% of nominal value unless current limited. Meaning that if output current is too high, the voltage will...

Created on: 19 February 2014

FEATURES ● High Quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories for simplified two-wire measuring system.● Two insulation test voltages(DC) : 250V and 500V.● Alternation voltage measurement.● Battery life indicator.● Fuse protected.     SPECIFICATIONS       Earth Resistance     Measuring system Earth resistance by constant current inverter 820Hz, 2mA approx. Measuring Ranges Earth resistance:     0-12/0-120/0-1200Ω Earth voltage:     0-30V AC   40-500Hz Accuracy Earth resistance:     ±3% F.S. Earth voltage:     ±2.5% F.S. Insulation     Test voltage(DC V) 250V 500V Measuring ranges 0-100MΩ 0-200MΩ Output voltage on open circuit Rated test voltage +10% ...