Category: Megger
Created on: 15 May 2014

Lightweight portable unit for field use Simple, semi-automatic operation Suitable for all oil breakdown testing to 60 kV Automatic 1 minute timer for easy withstand testing

Category: Megger
Created on: 15 May 2014

Simple manual or automatic operation 120 V 60 Hz operation User-selectable PASS/FAIL limits Fast test times selectable from 1s Ground bond testing at 25 A, 10 A and 200 mA Differential, touch and substitute ground leakage testing

Category: Megger
Created on: 15 May 2014

Simple Operation Warble Tone Generator Velocity factor from 0.30 to 0.99 Range to 10,000 ft (3 km) Tough ABS case IP54 environmental protection Carry case and test leads included

Category: Megger
Created on: 15 May 2014

Backlit graphics monochrome LCD (256 x 128) Adjustable display contrast Resolution to 0.1 m For use on Telecom TNV-3 circuit, or 150V CAT IV power circuits Power blocking filter not required Environmental protection to IP54 2ns pulse for near end fault location AUTO option selecting gain and pulse for each range Display distance in metres or feet Uses five AA (LR6) primary cells

Category: Megger
Created on: 15 May 2014

Full autoranging for measuring the lenght of power, telphony, CATV, and LAN cables, provides distance to an open or short. Extra large, high resolution backlit LCD. Automatic output impedance control of 25, 50, 75, 100, 125, or 150 ohms. User-friendly menu on screen operation. Cable length calibration function. Internal library of 39 standard cable types

Category: Megger
Created on: 15 May 2014

AC and DC voltage from 6 to 1000 V Resistance / Continuity (acoustically) 0 to 2 kΩ RCD function test Two pole phase sequence indication LCD display CAT IV 1000 V rating Exhausted battery warning indicator Auto power off

Category: Megger
Created on: 15 May 2014

Single- and three-phase transformer testing Fast, easy hand-held operation. Powered by six standard “AA” alkaline batteries; no charger needed. Provides up to 12 hours of field operation. Measures turns ratio range of 10,000:1, with a high accuracy (±0.1%, 0.8 to 2000) at a low excitation voltage Records ratio errors for bushing CTs to an accuracy of±0.1% nameplate. This reduces the need for additional test equipment and improves set-up time. Perfect for meter shops, the TTR20 can be used for inspection purposes to determine the no-load accuracy of most CTs and PTs. It also can be used to determine the need to test potentially faulty CTs and PTs. Automatic self-calibration for each test. Simple, one-button operation Quick-start guide on front panel

Created on: 30 January 2014

The Motor101A measures and records on and off status changes for motors or other equipment drawing up to 200 Amps. The state change occurs when the current switch exceeds the 150mA set point. This allows for most basic equipment to be monitored. The current switch monitors whether there is current passing through a wire around which it is clamped. When the current exceeds 150mA’s, the output changes and provides a voltage for the Motor101A to measure. The device can hold up to 406,323 state changes, but memory will only be used if the status has changed. The device can be programmed to check for status changes 4 times per second up to once every 24 hours. The Motor101A-NC includes the data logger and current switch. The Motor101A-C includes a data logger, current switch and an IFC200 interface cable.