By Brands
Brands
pH, mV, Conductivity, TDS, Resistivity, Salinity, Concentration and Temperature measurement functions. 0.001pH, 0.1mV, 0.001µS/cm, 0.001mg/L and 0.1°C / °F Resolution. Programmable Temperature Coefficient for conductivity measurement. Auto / Manual Temperature Compensation for pH and conductivity measurement. Practical Salinity in the Range of 0 to 42.0, in accordance with UNESCO data measurement. Dual display with temperature Simultaneously. Easy & Fast to operate. Ideal for most water application. Available cell constant of K=0.1, K=1.0 and K=10. 99 sets manual data memory and read function. 2250 sets auto datalogging capacity. USB interface. Indication of pH Electrode status.
Fast and Easy pH measurement Dual LCD display shows PH/℃& ℉ or mV/ ℃&℉ simultaneously Logging 99 readings
1 Φ 2W, 1 Φ 3W,3 Φ 3W,3 Φ 4W RS-232 interface to talk with PC 4 digits with dual display LCD Amp / Voltage f requency measurement Dual display KW+PF , KVA+PF , V+A 4000 continuity point data logger , 25 point manual data logger True power / apparent power / power factor measurement True RMS. V , A , W , cap , lnd , phase indicator MIN / MAX measurement Peak hold detector Dual display A+Hz , V+Hz EN61010-1 600V Installation CAT III Pollution Degree 2
HVAC Application: Check current draw in motors and compressors. Use MAX/MIN/Recording in the temperature mode to assess efficiency. Test run/start capacitors. Confirm low voltage control signals. Measure flame safeguard device current draw. Confirm power sources. Analyze temperature and voltage or current data with the aid of the time stamp. Insulation test up to 100M Ω. Electrical Application: Check for energized circuits and balance loads. 1 Φ /3 Φ (3P3W/3P4W)Power analyzer. Evaluate electrical contacts. Capture motor in-rush current readings. Determine peak power demand periods. Verify line voltage stability. Monitor motors and other loads for excess heat. Check motor run/start capacitor values.
Compact Size Trms KW measurement AC/DC Current Measurement (AC 600A/DC 600A) 600V AC & 600V DC, Ohm/Continuity Beeper 600 V AC & 600 V DC. Ohm/Continuity Beeper One Touch DCA Zero
Isolated Input Protection of 350Vp-p between any two inputs. Highly accurate thermometer with thermocoupleK, J, E, T, R, S, N, L, U, B, C types. 4 input function T1/T2/T3/T4 temperature display. Programmable Hi – Lo alarm for 4 inputs. Display of MAX, MIN, MAX–MIN and AVG values of 4 inputs. Independent Input Setup(type of thermocouple,Hi – Lo alarm values). Memory and Read function (99 sets) 512KB auto datalogging capacity(4 input:36000 sets /1 input: 100000 sets USB interface.
Max Hold Function Data Hold Function Aux output JACKS T1-T2 differential measurement
Type K. J. E. T. thermocouple input Dual channels with multi-functions (T1, T2 & T1-T2) Built-in thermo printer with programable time internal setting