Products

  • Filter
Created on: 14 February 2014

Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion Broad range of measurement, from 1 µA up to 60 A, for all installation needs Advanced shielding to ensure accurate results when measuring near other conductors The high durability clamp construction can withstand over 50,000 operations - added ruggedness that extends the life of your clamp Easy-to-carry, pocket-sized clamp with wide 40 mm (1.5 in) jaw size Handy "Display-Hold" button for capturing readings in hard- to-reach places Auto power-off, with warning buzzer, saves battery life Conformance to IEC1010 and EMC standard for confident measurements Meets all of the applications and performance classes in safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances

Created on: 14 February 2014

AC/DC current: Clamp-on measurement of ac current up to 1400 A rms and dc current up to 2000 A without breaking the circuit Highest safety rating: 600 V CAT IV power analyzer is rated for use at the service entrance Accurate in noisy environments: Clamp meter performs even with distorted waveforms present on electronic loads with low-pass filter Data logging: Identify intermittent faults by logging any power quality parameter for minutes, or over a month, including harmonics Verify batteries: Direct measurement of dc ripple (%) for battery and dc systems Troubleshoot harmonics: Analyze and log harmonics digitally or graphically Inrush current: Capture and analyze nuisance tripping, from 3 seconds to 300 seconds Easy to use: Easily confirm power meter setup with large backlit color display of waveforms and trends 3-Phase power: Built in capability for balanced loads View graphs and generate reports: Use power analyzer with included Power Log software

Created on: 14 February 2014

Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements Small body and jaws fit perfectly in your hand and into tight places Handy 'Display Hold' button keeps measurements on the display Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch) Large, backlit display (on most models) is easy-to-see Auto shut-off maximizes battery life so the meter works when you need it Three year warranty

Created on: 14 February 2014

Measure mA signals for PLC and control system analog I/O Measure 4 to 20 mA output signals from transmitters without breaking the loop Best in class 0.2 % accuracy Resolution and sensitivity to 0.01 mA Hold function captures and displays changing measurements Dual backlit display with both mA measurement and percent of 4 to 20 mA span Measurement Spotlight illuminates hard to see wires in dark enclosures Detachable clamp with extension cable for measurements in tight locations Measure 10 to 50 mA signals in older control systems using the 99.9 mA range Automatic power off after 15 minutes and 2 minute automatic off for backlight and spotlight

Created on: 14 February 2014

Measure 4 to 20 mA signals without ”breaking the loop” just like the innovative and popular Fluke 771 Process Milliamp Clamp meter Source 4 to 20 mA signals for testing control system I/O or I/Ps Simulate 4 to 20 mA signals for testing control system I/O Measure 4 to 20 mA signals with in-circuit measurement Simultaneously measure mA in-circuit with 24 V loop power for powering and testing transmitters Source mA output signals in a linear ramp or 25 % step output– Automatically change the 4 to 20 mA output for remote testing Power saving features, auto-off, backlight timeout extend battery life

Created on: 14 February 2014

DC voltage measurement to verify 24 V power supplies or voltage I/O signals Source DC voltage to test input devices that accept a 1 to 5 volt or 0 to 10 volt signal Scaled mA output provides a continuous mA signal that corresponds to the 4 to 20 mA signal measured by the mA clamp Output mA signal enables a logging DMM or other device to record the 4 to 20 mA signal without breaking the loop mA in/out: simultaneously measure the mA signal with the clamp and source a mA signal Apply a mA input signal to a device and measure its 4 to 20 mA output on devices such as valves or mA isolators Voltage output linear ramp or 25% step output Automatically change the voltage output for remote testing

Created on: 14 February 2014

VCHEK LoZ low impedance measurement function allows for simultaneous voltage or continuity testing A large backlit display provides easy visibility in low-lit areas True-rms ac for accurate measurements on non-linear loads Record signal fluctuations using the Min/Max function Integral holster with probe holders for easy storage Auto and Manual ranging Meets measurements category CAT III 600V and CAT IV 300V standards for a higher level of safety The optional TPAK magnetic hanger allows the user hands-free Flexibility Ideal for Utility Linesmen and Line Electricians Great for: Revenue meter tests (for meter sets and re-connects) Capacitor checks Absence of presence of voltage Continuity, connections, or basic wiring checks Electrical testing where ghost voltage may be present

Created on: 14 February 2014

AutoVolt: automatic AC/DC voltage selection Large white LED backlight to work in poorly lit areas Resistance and continuity Min/Max/Average to record signal fluctuations CAT III 600 V safety rated