Products
This Hewlett Packard HBSW-8200 Bar Code Wand reads eight common bar code symbologies. Code 39, Interleave 2 or 5, UPC A and E, EAN 8 and 13, Codabar, Code 128, Code 11, Code 93, and MSI Code. Programmable via bar code labels or escape sequences. LED indicates when a bar code has been correctly decoded. Resolution, 0.19 mm. Usable from -20 °C to 65 °C, in ambient light to 100,00 lux. EMI compliance per FCC part 15 Class B. ESD immunity, 25 kV. Supports the scanned entry of procedure identification, tag ID, serial number, and operator ID to a Fluke 743 Documenting Process Calibrator.
Shielded four conductor cable terminated with a 9-socket D-subminiature connector and a 9-pin D-subminiature connector. Provides interconnection and pin translation between a Fluke 743 Documenting Process Calibrator and a Hewlett Packard HBSW-8200 Bar Code Wand. Overall length approximately 15 cm One year warranty
Very accurate current shunt to use for verification and calibration of process control loops. Can be used with accurate voltmeters for calibration purposes Can be used with Fluke 74X series in mA/mA applications (74X will display mA/mA automatically) One year warranty
Measuring Range selectable per software: 30A to 3000A 60A to 6000A Peak current for sinusoidal currents: 10kA 19kA Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable
Measuring Range selectable per software: 2A to 200A 10A to 1000A Peak current for sinusoidal currents: 480A 2700A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 600 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable
Measuring Range selectable per software: 1A to 100A 5A to 500A Peak current for sinusoidal currents: 240A 1350A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5° Jaw Opening 45 cm length 2 m cable
Measuring Range selectable per software 1 A to 100 A 5 A to 500 A Peak current for sinusoidal currents 240 A 1350 A Intrinsic error 1% Frequency Range 45 Hz to 3.0 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening 45 cm length 2 m cable Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)
Measuring Range selectable per software:0.2 A to 20 A 2 A to 200 A Peak current for sinusoidal currents74 A 300 A Intrinsic error 0.5% Frequency Range 40 Hz to 10 kHz Operating Voltage 300 V CAT IV Phase Error 0.5 ° Jaw Opening < 15 mm diameter or 15 x 17 mm bus bars Errors in % of measuring range at 23 °C ± 2 K; 74 °F ± 2 K, for 48 to 65 Hz Phase angle error at nominal current Imax maximum current without time limit (for ac and dc shunts)