Products

  • Filter
Created on: 15 May 2014

Continuity:20/200Ω200mA Test Current • Insulation:500/1000V, 20/200MΩ1mA Rated Test Current • Loop Impedance:20/2000Ω15mA Test Current at 2000Ω (No RCD Trip) • RCD:10/30/100/300/500mAx1/2, x1, Fast Trip(40ms), DC, Auto Ramp • Test of a large kind of RCD's:Standard, Selective, AC and A(DC sensitive breakers) • Uc(Contact Voltage): 100V • Designed to IEC 61010-1, IEC 61557 • Data Memory:300 measured results • The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

Created on: 15 May 2014

Continuity Measurement Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display. Insulation Measurement Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display. Loop Impedance Measurement A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's. A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW...

Category: Combi Tester
Created on: 15 May 2014

Kew Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results. • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater. • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range. • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current. • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings. • Test of a large kind of RCD's:Standard, Selective, AC and A (DC sensitive breakers). • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. • RCD Ramp test in order to indicate the actual tripping current of RCD. • Contact Voltage Reading (UC). with two selectable contact voltage limits (50 and 25V). • Visual indication of correct wiring status and automatic lock-out if test resistors overheats. • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54. • The...

Created on: 15 May 2014

The Model 6202 is a hand-held portable appliance tester, performing four functions to ensure the Safety of Class I, Class II and Class III 230V appliances. And also can measure the mains voltage.Readings are displayed on a large liquid crystal display (LCD) below which are eight LEDs which unambiguously display a pass or fail indication for threshold values dictated by DIN VDE 0701/0702

Created on: 15 May 2014

The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage. Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.

Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020, 6300, 6305, 6310, 6315

Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 * When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.

Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 * When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.