testo 320 flue gas analyzer; incl. O2-/CO sensor without H2-compensation, incl. calibration protocol; graphic display; High-resolution graphic display TÜV-tested according to EN 50379, Parts 1-3 Sensor exchange by the user Memory up to 500 measurement protcols
testo 310 incl. battery and calibration protocol for the measurement of O2, CO, hPa and °C; probe 180 mm with cone; case; mains unit incl. cable; silicon hose for pressure measurement; particle filter 5 off. Robust and light instrument for daily use 30 seconds sensor zeroing O2 and CO measurement Integrated magnets for easy fixing to burner
testo 310 incl. battery and calibration protocol for the measurement of O2, CO, hPa and °C; IR printer (0554 3100); probe 180 mm with cone; case; mains unit incl. cable; silicon hose for pressure measurement; particle filter 5 off; 2 rolls spare thermal paper for printer. Robust and light instrument for daily use 30 seconds sensor zeroing Integrated condensate trap Integrated magnets for easy fixing to burne
electronic gas leak detector with flexible measurement probe, mains charger and earphones Optical and audible alarm with bar display for increasing and dangerous gas concentrations Integrated pump Trend display shows maximum leakage Flexible measurement probe for inaccessible places Meas. range10 ppm to 4,0 Vol. % CH4 10 ppm to 1,9 Vol. % C3H8 10 ppm to 4,0 Vol. % H21st alarm limit200 ppm CH4 100 ppm C3H8 200 ppm H22nd alarm limit10.000 ppm CH4 5.000 ppm C3H8 10.000 ppm H2Battery life6 h
HIGH ACCURACY AND RESOLUTION UP TO 0.001mm or 0.0001 inch MEASURING ULTRA THIN SAMPLE AS LOW AS 0.15mm or 0.006 inch DISPLAY UNITS : IMPERIAL and METRIC AUTOMATIC SELF CALIBRATION COUPLANT INDICATOR AUTOMATIC POWER OFF DEVICE HIGH-LOW LIMIT ALARM LCD BRIGHTNESS ADJUST LOW BATTERY INDICATOR STANDARD DELIVERY: Main Processor with Calibration block (4.00 mm) Precision Probe (D11R) with Replaceable Delay Tip Coupling Paste Operation Manual Consumer-Type 2 AA Type Alkaline Battery (3 Volt) Carrying Case
HIGH ACCURACY AND RESOLUTION UP TO 0.001mm or 0.0001 inch MEASURING ULTRA THIN SAMPLE AS LOW AS 0.15mm or 0.006 inch DISPLAY UNITS : IMPERIAL and METRIC AUTOMATIC SELF CALIBRATION COUPLANT INDICATOR AUTOMATIC POWER OFF DEVICE HIGH-LOW LIMIT ALARM LCD BRIGHTNESS ADJUST LOW BATTERY INDICTOR TECHNICAL SPECIFICATIONS: Measuring Range (for steel) Interface-Echo Mode: (I-E or Standard Mode) 1.50mm – 20.0mm (0.059in – 0.787 in) Echo-Echo Mode: (E-E or High Precision Mode) 0.15mm – 10.0mm (0.006in – 0.394in) Measuring Accuracy ±0.005mm or 0.0002 inch (if thickness < 3mm) ±0.05mm or 0.002 inch (if thickness < 20mm) Display Resolution mm : 0.1 / 0.01 / 0.001 inch : 0.01 / 0.001 / 0.0001 Sound Velocity Range 1000 to 9999 m/sec (0.0394 – 0.3936 inch/ms) Measuring Refresh Frequency 4Hz in normal mode, up to 25Hz Memory Capacity 500 test values Multiple Calibrations One point or Two Point Display LCD 42×57mm LCD size with EI backlight and adjustable contrast, font size up to 13.75mm (0.54 inch) Power...
*Color OLED 320x240 Pixels Display *Live Simultaneous Color A-Scan and Thickness Display *Control of Gain, Blanking, Gate, Range, Delay, RF and Rectify Modes *Time-based B-Scan Display *Echo-Echo Mode,Thru Paint & Coatings
Color 320x240 Pixels Display A-Scan Snapshot Echo-Echo Mode(Thru Paint & Coatings) Stores 100,000 Readings Gain: Low, Medium or High for varying test conditions