Products
10 Display Easy - to - View LCD Screen. Connectors for 4 Current Sensing Clamps. 1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement. True RMS Sensing. Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement. Phase sequency indicator function. Backlight display function. Manual Data Memory and Read (99 sets). Data Logging (504KB Memory, 20,000 sets) Programmable Trigger - Points and Start / Stop Time. RS-232 Optical Interface with three phase voltage / current Waveform display and Harmonic analysis. Easy - to - use Push - Button Operation. Light Weight, Portable Design.
Wide spectral range. Excellent long term stability. Cosine corrected. Automatic transmission measurements. Select either power or transmission. Solar energy power or transmission. Current time setting function. User calibration factor setting function. End-mount light sensor. Select either W/m2 or Btu / (ft2*h) units Data Hold / MAX / AVG modes. Data Memory and Read function. (99 sets.) Auto Data memory (TES-1333) RS232 interface to PC. (TES-1333R)
4 digit LCD reading. Wide spectral range. Excellent long term stability. Cosine corrected. Automatic transmission measurements. Select either power or transmission. Solar energy measurement. Current time setting function. User calibration factor setting function. End-mount light sensor. Select either W/m2 or Btu / (ft2 x h) units. Data hold/MAX/MIN/AVG modes. Auto Data Memory function. (microSD CARD 2GB) Manual Data Memory and Read function. (99 sets) Auto power off function. USB interface.
4-digit LCD reading. Spectral Sensitivity close to CIE photopic Curve. Auto ranging from 0.05 to 7000 lumens. Accurate and Instant response. Data Hold function. Data memory and read function. Zero function. Ratio function. Sort function. Comparator function. Best for measuring : LEDs, Small lamps, Fiber illuminators. Auto power off function. RS232 Interface. Easy to use. Adapters kit : 2/3/4/5/8/10m/m
Check the color difference between two samples. Color difference displayed Δ(L*,a*,b*) Δ(E*ab,C*ab, H*ab) Δ(Y, x, y) Δ(X, Y, Z) or Δ(Rs, Gs, Bs) Color space displayed (L*, a*, b*) (L*, C*ab, hab) (Y, x, y) (X, Y, Z) or (Rs, Gs, Bs) Maximum, Minimum and Average function. Tolerance function. Auto memory (99 sets) & Read function. RS232 interface.
Measuring range: 0 to 150 m/sec Robust, thermal silicon chip sensor Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12") Includes 5-point calibration certificate Measuring range: -50 to 400 ° C Minimum flow required: 2 m/sec Accuracy: +/-3 percent of reading, /-0.4 percent of final value Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin Response time: t90 approximately 5 seconds Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA)
Measuring range: 0 to 80 Nm/sec Robust, thermal silicon chip sensor Penetration probe design, versatile use for pipe diameters from DN 50 (2") to DN 300 (12") Includes 5-point calibration certificate Minimum flow required: 1 m/sec Ambient temperature: -10 to +60° C Accuracy: +/-3 percent of reading, /-0.4 percent of final value Temperature dependency: compensated at 25 ° C, deviating temperatures: 0.1 percent of reading/kelvin Response time: t90 approximately 5 seconds Voltage supply: 12 to 24 Vdc +/-10 percent , power consumption less than 100 mA (starting current briefly 500 mA)
Automatic mean calculation and volume flow measurement Automatic allocation of duct cross-section to location (max. 99 locations) Internal data logger (3,000 readings) Simultaneous measurement of up to 6 parameters

