• Filter
Category: Transmitters
Created on: 21 February 2014

Highest reliability Calculation of the most important trace humidity variables Adjustment report Convenient operation Analog output 4 to 20 mA, 2-wire technology Ambient temperature: -20 to 70 ° C Storage temperature: -40 to 80 ° C Protection class: IP 65 Resolution: 12 bit Accuracy: +/- 40 microA Analog output 4 to 20 mA (2-wire technology)

Category: Transmitters
Created on: 21 February 2014

Highest reliability Calculation of the most important trace humidity variables Adjustment report Convenient operation Analog output 4 to 20 mA, 2-wire technology

Category: Transmitters
Created on: 21 February 2014

Highest reliability Calculation of the most important trace humidity variables Adjustment report Convenient operation Analog output 4 to 20 mA, 2-wire technology

Category: Transmitters
Created on: 21 February 2014

Reliable measurement of trace humidity User-friendly operation with display and control buttons Calculation of the most important trace humidity variables, also ppm Protocolled fine adjustment at -40 °C tpd 4 to 20 mA in two-wire technology Plastic, polyacrylamide housing material Ambient temperature: -20 to 70 degree C Storage temperature: -40 to 80 degree C Protection class: IP 65 Resolution: 12 bit Accuracy: +/- 40 microA

Created on: 21 February 2014

Combined penetration tip with temperature probe Measuring tip can be changed by user Maintenance-free gel electrolyte Backlit display Audible key feedback 2 line display Automatic full-scale value recognition 1, 2 or 3 point calibration possible pH tip embedded in break-proof plastic Measurement tip can be replaced by user 0 to 14 pH Range +/-0.02 pH Accuracy 0.01 pH Resolution

Created on: 21 February 2014

Combined penetration tip with temperature probe Measuring tip can be changed by user Maintenance-free gel electrolyte Backlit display Audible key feedback 2 line display Automatic full-scale value recognition 1, 2 or 3 point calibration possible pH tip embedded in break-proof plastic Includes on-hand pH/° C measuring instrument with penetration probe, storage cap Also include gel and calibration bottles (250ml pH 4+7), belt/wall holder and aluminium case Measuring range: 0 to 14 pH +/-0.02 pH accuracy 0 to 14 pH Range 0.01 pH Resolution

Created on: 21 February 2014

Maintenance-free gel electrolyte Automatic full-scale value recognition Built-in temperature probe 1, 2 or 3 point calibration possible TopSafe: Robust, water-tight, hygienic and dishwasher-proof protection case (IP68)

Created on: 21 February 2014

Maintenance-free gel electrolyte Automatic full-scale value recognition Built-in temperature probe 1, 2 or 3 point calibration possible TopSafe: Robust, water-tight, hygienic and dishwasher-proof protection case (IP68)