• Filter
Created on: 16 February 2014

Compact, high precision power analyzers – easy to carry and save working space Simple user interface ensures easy, intuitive operation Standard configurations allow users to specify the exact functionality required for their own unique application Accurately display dynamic events on all phases at exactly the same point in time with simultaneous parallel acquisition of all phases All inputs are galvanically isolated to avoid short circuits in all applications.Voltage, current and power harmonics up to the 40th FFT analysis, vector diagram display, recorder function and Digital Oscilloscope (DSO) mode included User-selectable average time – from 15 ms up to 3600 s – for dynamic measurements 4 MB on-board memory for storage of measured values RS232 and USB available as standard; optional IEEE 488/Ethernet available Optional process interface available to measure torque and speed with external sensors; includes four analog outputs for easy use on motor and drive applications 341 kHz or 1 MHz sample rates for detailed signal analysis Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision Includes Fluke NormaView PC software for setup, data download,...

Created on: 16 February 2014

Compact, high precision power analyzers – easy to carry and save working space Simple user interface ensures easy, intuitive operation Standard configurations allow users to specify the exact functionality required for their own unique application Accurately display dynamic events on all phases at exactly the same point in time with simultaneous parallel acquisition of all phases All inputs are galvanically isolated to avoid short circuits in all applications.Voltage, current and power harmonics up to the 40th FFT analysis, vector diagram display, recorder function and Digital Oscilloscope (DSO) mode included User-selectable average time – from 15 ms up to 3600 s – for dynamic measurements 4 MB on-board memory for storage of measured values RS232 and USB available as standard; optional IEEE 488/Ethernet available Optional process interface available to measure torque and speed with external sensors; includes four analog outputs for easy use on motor and drive applications 341 kHz or 1 MHz sample rates for detailed signal analysis Bandwidth from dc to 3 MHz / 10 MHz for reliable measurement precision Includes Fluke NormaView PC software for setup, data download,...

Created on: 16 February 2014

Energy loss calculator Power inverter efficiency Power Wave data capture Wave form capture Automatic Transient Mode Fully Class-A compliant Mains signaling 400 Hz measurement Troubleshoot real-time Highest safety rating in the industry Measure all three phases and neutral Automatic Trending System-Monitor Logger function View graphs and generate reports Seven hours operating time per charge on Li-ion battery pack

Created on: 16 February 2014

Energy loss calculator Power inverter efficiency Power Wave data capture Wave form capture Automatic Transient Mode Fully Class-A compliant Mains signaling Troubleshoot real-time Highest safety rating in the industry Measure all three phases and neutral Automatic Trending System-Monitor Logger function View graphs and generate reports Seven hours operating time per charge on Li-ion battery pack

Created on: 16 February 2014

Energy loss calculator Power inverter efficiency Troubleshoot real-time Highest safety rating in the industry Measure all three phases and neutral Automatic Trending System-Monitor Logger function View graphs and generate reports Seven hours operating time per charge on Li-ion battery pack

Created on: 16 February 2014

Key Features High sensitivity measurement of rate and dose simultaneously, with the capability to record peak rate Detects skin-dose (beta particle) and deep-dose (gamma) and X-ray radioactivity Requires no adjustments; simple two button process Provides promptly read, correct value through auto-ranging capability Easily visible inside truck trailers and other low-light situations with automated backlight Works dependably inside or outside thanks to sealed case 30 % more precise than other available meters Delivers more than one week of uninterrupted functioning with two 9-volt alkaline batteries Proven in use by state and local governmental emergency response professionals, state inspectors, HAZMAT teams and nuclear power workers Measures both dose and dose-rate Valuable for contamination-detection, general radiation area metering, radiation-level monitoring, and hazardous materials assessment Rugged Fluke design Easy touch keys Screen - Bright, highly visible colors Auto-ranging and auto-zeroing RS-232 communications interface with optional Windows-based Excel add-in for data logging Ergonomic, anti-fatigue handle with replaceable grip, wrist strap and...

Category: ScopeMeters
Created on: 16 February 2014

Two electrically isolated inputs  CAT IV 600V safety rated Fast sampling rate, up to 5GS/s with up to 200 ps resolution Deep memory: 10,000 samples per channel waveform capture so you can zoom in on the details Connect-and-View continuous auto-trigger, single shot, pulse width, and video triggering ScopeRecord roll mode, capture waveform sample data for up to 48 hours TrendPlot, trend measurement readings for up to 22 days Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s) IP-51 rated for dust and drip proof to withstand harsh environments Isolated USB ports for memory devices and PC connectivity Li-Ion battery for extended operating timespan Charge spare battery using optional external battery charger EBC290 Easy-access battery door to make it easy to swap batteries

Category: ScopeMeters
Created on: 16 February 2014

IEC 61010 1000V CAT III/600V CAT IV safety rating Four fully isolated floating input channels with up to 2.5 GS/s real-time sampling rate 8ns glitch detect 10,000 sample deep memory per channel for displaying high resolution waveform details Four input channels let you log inputs and measurements over time: Four meter measurements Four TrendPlot traces Four Scope Record traces High capacity Li-ion batteries offer up to seven hours operation Battery access door to easily swap out batteries for extended operation Two electrically isolated USB ports, mini USB-A for PC connectivity and a USB memory device port Security slot to lock down instrument using standard Kensington PC lock Screw insert for standard camera mounting accessories 200 MHz bandwidth, up to 2.5 GS/s real time sample rate and up to 400 pico seconds resolution Connect-and-View to easily trigger on and display even complex waveforms TrendPlot and ScopeRecord to capture or plot waveforms and measurements over extended time spans Replay last 100 screens to go back in time to see waveform anomalies Environmentally tested to meet IP51 dust-proof and drip-proof rating and withstand 3g vibration or 30...