Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac(40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1500g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 30V EN 61326-1

Created on: 18 February 2014

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories    for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx Open circuit indication LED will be unlit Dimensions 205(L) × 90(W) × 55(D)mm Weight (battery included) Approx. 514g Power source 1.5V (AA) × 6 Safety standards EN 61010-1 CAT III 30V EN 61326-1

Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 210(L) × 210(W) × 100(D)mm Weight (battery included) Approx. 1370g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 30V EN 61326-1

Created on: 18 February 2014

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● Test leads are supplied as standard accessories    for simplified two-wire measuring system.● Battery operated.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 170(L) × 165(W) × 92(D)mm Weight (battery included) Approx. 1000g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT III 150V EN 61326-1

Created on: 18 February 2014

● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth   resistance without tripping earth leakage current   breakers in the circuit under test.● In addition to facilitating for precision measurement,    test leads for simplified two-wire measuring system    also are supplied as standard accessories.● Battery operated.● Battery life indicator.   ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-12Ω / 0-120Ω / 0-1200Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 175(L) × 85(W) × 75(D)mm Weight (battery included) Approx. 600g Power source 1.5V (AA) × 8 Safety standards EN 61010-1 CAT IV 30V   EN 61326-1

Created on: 18 February 2014

● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage. ● The timer operates automatically for about three to    five minutes when the “PUSH BUTTON SWITCH”    and “TIMER ON BUTTON” are pressed together.  ● This will keep test “ON” for the duration of the timer.● Battery check function. ● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-10Ω / 0-100Ω / 0-1000Ω Earth voltage 0-30 Vac (40-500Hz) Accuracy Earth resistance ±3% of full scale Earth voltage ±2.5% of full scale Measuring system Earth resistance by constant current inverter 820 Hz, 2mA approx. Open circuit indication LED will be unlit Dimensions 163(L) × 100(W) × 50(D)mm Weight (battery included) Approx. 460g Power source 1.5V (AA) × 6 Safety standards IEC 1010 CAT II 30V

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without    tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified    two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) at 200/2000Ω ±(2%rdg+0.1Ω) at 20Ω Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “   “symbol appears on the display Data hold ...

Created on: 18 February 2014

FEATURES ● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without    tripping earth leakage current breakers in the circuit under test.● The leads are supplied as standard accessories for simplified    two-wire measuring system.● Battery operated.● Data hold function.● Battery test indication.● Calibration performed with supplied test leads.     SPECIFICATIONS         Measuring ranges Earth resistance 0-20Ω / 0-200Ω / 0-2000Ω Earth voltage 0-200 Vac(40-500Hz) Accuracy Earth resistance ±(2%rdg+2dgt) or ±0.1Ω, which is greater Earth voltage ±(1%rdg+2dgt) Earth resistance resolution 0-20Ω : 0.01Ω   0-200Ω : 0.1Ω   0-2000Ω : 1Ω Measuring system Earth Resistance by constant current inverter 820Hz approx. 2mA Display 3½ digit (2000 counts) Open circuit indication LED will be unlit Low battery indication “  “symbol appears on the display Data hold ...