FEATURES ● The 865 PR is a detector with LEDs to show the de- tection better visible than neon. ● Three functions in one unit, including open phase, phase sequence and 3 phase motor rotation.● Designed for checking a wider range of 3 phase power source from 100V to 500V.● Indicates R.S.T LEDs which frequency range from 40Hz to 400Hz.● Wide range detection of motor frequency range from 2Hz to 400Hz.● Fixed magnets for convenient measurement. SPECIFICATIONS Measurement principle Contact Live Wire Input voltage 100-500Vac Frequency range 40Hz-400Hz Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 1m Dimensions 128(L) x 72(W) x 44(D)mm Weight (battery included) Approx. 220g Power source 9V (6F22) × 1 Safety standard EN 61010-1 CAT III 500V EN 61326-1 EN 61557-1 ...
FEATURES ● Three functions in one unit: open phase, phase sequence and motor rotation indication. ● Large size alligator clips for easy clipping onto switch- boards terminals. ● Highly reliable. ● Identifies 3 phase sequence and open phase check.● Ideal for installing conveyor lines, pump systems and interconnected drivers. SPECIFICATIONS Input voltage 100-500V AC Frequency range 45-70 Hz Circuit structure All electronic (not mechanical) Power requirement 9V (6F22) × 1 Power consumption Consumption current approx. 14mA of motor rotation field tester AC power consumption Approx. 7mA Dimensions 153(L) × 72(W) × 35(D)mm Weight (battery included) Approx. 200g Safety standard EN 61010-1 CAT III 500V EN 61326-1
FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence. SPECIFICATIONS Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31
FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence. SPECIFICATIONS Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31
FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence. SPECIFICATIONS Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31
FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence. SPECIFICATIONS Voltage 90V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 510g Safety standard IEC 1010 CAT II 600V
FEATURES ● Safely operates at low voltage ● Measures system voltage.● Measures capacitance of test point if system voltage is known.● Checks phase rotation of cables.● Phases out cables.● Rugged - comes with portable case.● Operates from potential test point of elbow connec-tors.● Battery operated. SPECIFICATIONS Voltage ranges 0~16kV / 0~32kV Accuracy ±8% (exclusive of tap capacitance variations) Tap capacitance setting 0.4 to 3.0 pF continuous per channel Frequency 50 or 60 Hz Dimensions 250(L) × 190(W) × 110(D)mm Weight (battery included) Approx. 1420g Power source 1.5V (AA) × 4 Safety standard EN 61326-1
FEATURES ● Rotary scale which presents only one scale in windows at one time to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach places.● Ω range ideal for checking the continuity or relays, transformers and motor coils.● TAUT BAND movement. SPECIFICATIONS AC A 10 / 30 / 100 / 300 / 1000A ±3% of F.S.(50/60Hz) AC V 150 / 300 / 750V ±3% of F.S. DC V ── Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 10A 50-400Hz for ACA 30 / 100 / 300 / 1000A Dimensions 227(L) × 73(W) × 33(D)mm Conductor size 52mm Max. Weight (battery Included) Approx. 460g