Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 20 February 2014

FEATURES ● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.     SPECIFICATIONS         AC A 6 / 30 / 60 / 300 / 600A ±3% of F.S.(50/60Hz) AC V 150 / 300 / 600V ±3% of F.S. DC V   ──   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 6A 50-400Hz for ACA 30 / 60 / 300 / 600A Dimensions 230(L) × 72(W) × 37(D)mm Conductor size 38mm Max. Weight (battery Included) Approx. 420g Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

Created on: 20 February 2014

FEATURES ● Designed for measuring AC current, AC voltage resistance and DC   voltage .● Rotary scale which presents only one scale in windows at one time   to avoid any possible reading errors.● Pointer lock function freezes the reading in dimly lit or hard to reach   places.● Ω range ideal for checking the continuity or relays, transformers and   motor coils.     SPECIFICATIONS         AC A 6 / 15 / 60 / 150 / 300A ±3% of F.S.(50/60Hz) AC V 300 / 600V ±3% of F.S. DC V 75V ±3% of F.S.   Ω 2kΩ ±3% of Scale length Frequency response 50 / 60Hz for ACA 6A 50-400Hz for ACA 15 / 60 / 150 / 300A Dimensions 230(L) × 72(W) × 37(D)mm Conductor size 38mm Max. Weight (battery Included) Approx. 420g Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

Created on: 20 February 2014

FEATURES ● 3½ digit liquid crystal display with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges     SPECIFICATIONS               AC A 200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz) AC V 200 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz)   Ω 200Ω ±(1.5%rdg+2dgt) Buzzer Resistance is less then 30Ω Peak hold ˇ Conductor size 55mm Max. Operating temperature 0ºC ~ 40ºC Humidity 85% Current consumption Approx. 10mA Dimensions  245(L) × 70(W) × 41.7(D)mm Weight (battery Included) Approx. 480g Power source 9V(6F22) × 1

Created on: 20 February 2014

FEATURES ● Full auto range for V.A and Ω functions.              ● Data hold function freezes the reading in dimly lit or    hard to reach places.        ● Low battery indication.        ● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal     parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays    transformers and motor coils.     SPECIFICATIONS         AC A 400A ±(2.0%rdg+3dgt) : 50/60Hz AC V 400 / 600V ±(1.2%rdg+3dgt) : 40-500Hz   Ω 4kΩ ±(1.5%rdg+3dgt) Buzzer sounds < 100Ω Conductor size 27mm Max. Low battery Indication   Dimensions 197(L) × 65(W) × 33(D)mm Weight (battery Included) Approx. 250g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT II 600V EN 61010-2-32

Created on: 20 February 2014

FEATURES ● 4000 - count LCD.● Full automatic measurement.      ◎ Voltage measurement.      ◎ Current measurement.      ◎ Resistor measurement.      ◎ Capacitor measurement      ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded    banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 400.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt)     40~500Hz DC A 400.0/2000A 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) DC V 400.0mV/4.000/40.00/400.0/1000V...

Created on: 20 February 2014

FEATURES ● 2000 - count LCD.● Full automatic measurement.          ◎ Voltage measurement.          ◎ Current measurement.          ◎ Resistor measurement.          ◎ Capacitor measurement          ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded    banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 200.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 200.0mV ±(2.0%rdg+3dgt) 2.000/20.00/200.0/750V ±(1.5%rdg+3dgt) 40~500Hz DC A 200.0/2000A...

Created on: 20 February 2014

FEATURES ● 4000- count LCD.● Full automatic measurement.           ◎ Voltage measurement.           ◎ Current measurement.           ◎ Resistor measurement.           ◎ External frequency measurement.● Range change function.● Data Hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Max/Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded   banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 400.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(1.5%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.0%rdg+3dgt)     40~500Hz DC A 400.0/2000A...

Created on: 20 February 2014

FEATURES ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded    banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers    and motor coils.     SPECIFICATIONS         AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ─── LCD backlight display   ─── Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 420g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN...