Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 20 February 2014

FEATURES ● The RCB-1 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 2M. 7M. 10M. 20M. 30M. 50M. 100M. 200M. 500M. 1G. 2G. 5G. 10G. 20G. 50G. 100G. 200G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 5200g...

Created on: 20 February 2014

FEATURES ● The 880 AT is a simplified Version of an appliance tester which use    low voltage and low current to perform it's checks.● Application Example   The appliance is plugged into the mini appliance checker, then the   probe make contact with the protective conductor.● Other appliance checking   Washing Machine Toaster Iron Dish Washer   Stove     SPECIFICATIONS       ELECTRICAL       Resistance Ranges    The L-E led will lit when the resistance between Line    to Earth is lower than 1MΩ ±5% .    The N-E led will lit when the resistance between Neutral to Earth is lower    than 1MΩ±5%  The EARTH BOND led will lit when the resistance between the EARTH to the Probe is higher than 10Ω±5% . Test Current    Line to Earth test current is 9uA maximum.    Neutral to Earth test current is 9uA maximum.    Earth to Probe test current is 2.3mA maximum. Maximum...

Created on: 20 February 2014

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS         Output voltage H terminal: AC 415V (±20%) L terminal: AC 230V (±20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 128(L) x 72(W) x 45(D)mm Weight (battery included) Approx. 315g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

Created on: 20 February 2014

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS         Output voltage H terminal: AC 690V (±20%) L terminal: AC 100V (±20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 128(L) x 72(W) x 45(D)mm Weight (battery included) Approx. 315g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

Created on: 20 February 2014

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS Output voltage H terminal: AC 400V (± 20%) L terminal: AC 100V (± 20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 124(L) × 69(W) × 42(D)mm Weight (battery included) Approx. 305g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

Created on: 20 February 2014

FEATURES ● Input Voltage : 120V AC or 240V AC.● Standard 4.5-inch switchboard case.● Front panel mount.● 3 bi-colored LED indicators for "SYNC", "GEN" and "BUS".● 24 LEDs in a circle display the phase angle and the frequency differences between 2 networks.● 360° LED indication.● 12 o'clock position LED is bi-colored.     SPECIFICATIONS          LS-110 SYNC  (120V)   LS-110 SYNC (240V) Nominal Input Voltage 120V AC 240V AC Overload 1.25 × Nominal voltage Frequency Range 35~70Hz Scale SLOW / FAST Pointer LED 15 degrees / LED BUS LED (Bi-colored) Green :108V-132V AC Green :216V-264V AC Red :<108V   or   >132V AC Red :<216V   or   >264V AC GEN LED (Bi-colored) Green :108V-132V AC Green :216V-264V AC Red :<108V   or   >132V AC Red :<216V   or   >264V AC SYNC LED (Bi-colored) Green :"GEN" and "BUS" are...

Created on: 20 February 2014

Principle : Electrodynamometer type ● Accuracy : ±0.5% of full scale ● Scale Length : Approx. 135mm(5-3/8”) ● Scale Divisions : 120 ● Frequency Ranges : AC 25 to 1000Hz (COSO=1.0) (suitable for DC)                                      AC 25 to 500Hz (COSO=0.2)

Created on: 20 February 2014

Principle : Phase angle sensing transducer ● Rated Accuracy : ±3° phase angle ● Scale :    Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 Lag    Power Angle: Lead 90° – 0° – 90° Lag ● Effective Power Factor Measuring Range :    Lead 0.5 – 1.0 – 0.5 Lag ● Scale Length : Approx. 135mm(5-3/8”) ● Dimension :Bakelite with glass window ● Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz