Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 15 May 2014

Continuity:20/200Ω200mA Test Current • Insulation:500/1000V, 20/200MΩ1mA Rated Test Current • Loop Impedance:20/2000Ω15mA Test Current at 2000Ω (No RCD Trip) • RCD:10/30/100/300/500mAx1/2, x1, Fast Trip(40ms), DC, Auto Ramp • Test of a large kind of RCD's:Standard, Selective, AC and A(DC sensitive breakers) • Uc(Contact Voltage): 100V • Designed to IEC 61010-1, IEC 61557 • Data Memory:300 measured results • The stored data can be transferred to PC via Optical Adaptor Model 8212-USB or 8212-RS232C.

Created on: 15 May 2014

Continuity Measurement Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display. Insulation Measurement Three selectable test voltages 250V, 500V and 1000V. An auto-discharge function ensures that circuits are not hazardous after testing. A red LED gives warning of high voltage output during testing and discharging of the circuit. In case of connecting to a live circuit, a live circuit warning is given by flashing LED, buzzer and indication on the display. Loop Impedance Measurement A patented (ATT) low current loop impedance test enables high accuracy loop measurements and quick testing without tripping RCD's. A high current alternative is selectable for even higher accuracy and instantaneous results. The subsequent test will default to the low current test, this saves any inadvertent tripping of the RCD. The KEW...

Category: Combi Tester
Created on: 15 May 2014

Kew Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results. • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater. • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range. • Direct reading of Prospective Short Circuit Current (PSC) and earth fault current. • RCD tests at 0 and 180 degree phase angle switch permit quick tests and consistent readings. • Test of a large kind of RCD's:Standard, Selective, AC and A (DC sensitive breakers). • Constant current source circuitry ensures that a fluctuating mains voltage does not affect the accuracy of readings. • RCD Ramp test in order to indicate the actual tripping current of RCD. • Contact Voltage Reading (UC). with two selectable contact voltage limits (50 and 25V). • Visual indication of correct wiring status and automatic lock-out if test resistors overheats. • Designed to IEC 61010-1, IEC 61557 and high protection degree IP54. • The...

Created on: 15 May 2014

The Model 6202 is a hand-held portable appliance tester, performing four functions to ensure the Safety of Class I, Class II and Class III 230V appliances. And also can measure the mains voltage.Readings are displayed on a large liquid crystal display (LCD) below which are eight LEDs which unambiguously display a pass or fail indication for threshold values dictated by DIN VDE 0701/0702

Created on: 15 May 2014

The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage. Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760.

Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020, 6300, 6305, 6310, 6315

Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 * When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.

Category: Power Meter
Created on: 15 May 2014

Load current clamp sensor Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315 * When you use the sensors with KEW5010/5020, please check the "Applicable model list" to check if your KEW5010/5020 can be used with the sensors.