Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 15 May 2014

Can measure AC current up to 1000A • Flexible and light weight by the air core coil used at the sensor part • Designed to meet the international safety standardIEC 61010-1 CAT IV 300V, CAT III 600V Applicable model 5010/5020 (*), 6300, 6305, 6310, 6315

Created on: 15 May 2014

Applicable model 5010/5020 Conductor size Φ55 Rated current AC 1000A Output voltage AC 500mV/1000A (AC 0.5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.5Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2 Dimensions 170(L) x 105(W) x 48(D) mm Weight Approx.360g Accessories 9094 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Created on: 15 May 2014

Applicable model 5010/5020 Conductor size Φ40 Rated current AC 500A Output voltage AC 500mV/500A (AC 1mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 5350V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 1.9Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 600V pollution degree 2 Dimensions 128(L) x 81(W) x 36(D) mm Weight Approx.260g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Created on: 15 May 2014

Applicable model 5010/5020 Conductor size Φ24 Rated current AC 100A Output voltage AC 500mV/100A (AC 5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 9.5Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2 Dimensions 97(L) x 59(W) x 26(D) mm Weight Approx.150g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Created on: 15 May 2014

Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement.

Created on: 15 May 2014

Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement.

Created on: 15 May 2014

Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Conductor size Φ24 Rated current AC 30A Output voltage AC 1500mV/30A (AC 50mV/A) Accuracy 0~15A|±1.0%rdg±0.1mV (50/60Hz)|±2.0%rdg±0.2mV (40Hz~1kHz) 15~30A|±5.0%rdg (50/60Hz)|±10.0%rdg (45Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~50ºC, less than 85% RH (without condensation) Output impedance Approx. 90Ω Applicable standards IEC 61010-1:2001,IEC 61010-2-032:2002,CAT.III 300V pollution degree 2 Dimensions 100(L) x 60(W) x 26(D) mm Weight Approx.150g Accessories 9095 (Portable case), Instruction manual, Cable marker Option 7146 (Banana Φ4 adjuster plug)7185 (Extension Cable)

Created on: 15 May 2014

Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement.