FEATURES ● Large LCD : 68 × 34mm (2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial   sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.     SPECIFICATIONS       Measuring ranges 0-20Ω / 0-200Ω / 0-2kΩ Test frequency 1kHz Accuracy 20Ω:±2%rdg±2dgt or ±0.1Ω Which is greater 200Ω/2kΩ : ±2%rdg±2dgt Low battery indication “  “ Symbol appears on the display Data hold indication “  “ Symbol appears on the display Dimensions 175(L) × 85(W) × 75(D)mm Weight (battery included) Approx. 600g Power source 1.5V (AA) × 8 Safety standard EN 61010-1 CAT III 200V EN 61326-1

Created on: 20 February 2014

FEATURES ● Large LCD : 68 × 34mm(2.677" × 1.338").● True measurement of speaker systems actural impedance at 1kHz.● Three test ranges allow testing of home theater and commercial   sound systems.● Measures transformer impedances.● Battery operation.● Low battery indication.● Data hold function.● 0Ω adjustment.     SPECIFICATIONS       Measuring ranges 0-200Ω / 0-2kΩ / 0-20kΩ Test frequency 1kHz Accuracy 200Ω/2kΩ : ±2%rdg±2dgt 20kΩ : ±3%rdg±2dgt Low battery indication “  “ Symbol appears on the display Data hold indication “   “ Symbol appears on the display Dimensions 175(L) × 85(W) × 75(D)mm Weight (battery included) Approx. 600g Power source 1.5V (AA) × 8 Safety standard EN 61010-1 CAT III 200V EN 61326-1

Created on: 20 February 2014

FEATURES ● High quality Taut Band movement.● Battery operated.● Timer function for hands free use.● Battery indicator.● The tester measure with a frequency of 1kHz.● Measure speaker’s impedance.● Measure speaker lines (connected to load).● Help to calculate and check audio power systems.● Ideal for public address installation and maintenance.● Measure transformer impedances.     SPECIFICATIONS         Measuring system Constant current inverter with 1kHz approx. 2mA Measuring ranges 20Ω / 200Ω / 2kΩ Accuracy ± 2.5% of full scale Dimensions 163(L) × 100(W) × 50(D)mm Weight (battery included) Approx. 420g Power source 1.5V (AA) × 6    Safety standard EN 61010 CAT II 100V

Created on: 20 February 2014

FEATURES ● True measurement of speaker systems actual impedance at 1kHz.● Three test ranges (20Ω / 200Ω / 2000Ω) allow testing of home    theater and commercial sound systems.● Measures transformer impedances.● Battery operated.● Low battery indication.● Data hold function.● Timer function for continuous hands free operation.● The timer can last about 3-5 minutes when users press.● TEST ON/OFF button.     SPECIFICATIONS       Measuring ranges 0-20Ω / 0-200Ω / 0-2000Ω Test frequency 1kHz Accuracy 20Ω : ± 2%rdg±2dgt or ± 0.1Ω, which is greater 200Ω / 2000Ω : ± 2%rdg±2dgt Low battery indiction “  “ Symbol appears on the display Data hold indiction “  “ Symbol appears on the display Display LCD 3½ digit (2000 counts) Dimensions 205(L) × 90(W) × 55(D)mm Weight (battery included) Approx. 530g Power source 1.5V (AA) × 6 Safety standard EN 61010-1 CAT III 300V EN 61326-1

Created on: 20 February 2014

FEATURES ● x10 Model allows for more accurate   measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.     SPECIFICATIONS       Input/Output line connector 3 prong U.S. standard Max. Voltage/Ampere rating 120Vac(±10%)/10Aac Operating Temperature & Relative Humidity 0℃~50℃ Max.80%R.H. Weight Approx. 110g Dimensions 145(L) x 55(W) x 35(D)mm

Created on: 20 February 2014

FEATURES ● x10 Model allows for more accurate   measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.● 10cm plug cord for greater flexibility.     SPECIFICATIONS         Input plug US / Europe Output socket 3 prong U.S. standard Cord length 10cm Max. Voltage/Ampere rating 120Vac(±10%)/10Aac For ETL (UL 61010-1) 250Vac(±10%)/10A For CE (EN 61010-1) Operating Temperature & Relative Humidity 0℃~50℃ Max.80%R.H. Weight Approx. 135g Dimensions 145(L)x55(W)x35(H)mm

Created on: 20 February 2014

FEATURES ● 2000 counts.● DC Voltage measurement.● 4-wire resistance measurement.● Data hold function.● Low battery indication.● 9V DC power supply.● Measure battery types: Li-ion, Ni-Cd, Ni-MH● Simple operation.● Lead resistance and contact resistance eliminated.     SPECIFICATIONS       DC Voltage       Range 2V 20V 100V Resolution 1mV 10mV 100mV Accuracy ±(1%rdg+1dgt) ±(1%rdg+1dgt) ±(1%rdg+1dgt) Resistance       Range 200mΩ 2000mΩ 20Ω Resolution 0.1mΩ 1mΩ 10mΩ Accuracy ±(3%rdg+3dgt) ±(3%rdg+3dgt) ±(3%rdg+3 dgt) General       Low battery indication "  " sign appears on the display when the battery voltage drops below accurate operating level. Dimensions 192(L) × 88.6(W) × 45.2(D)mm Weight (battery included) Approx. 360g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT I 100V EN...

Created on: 20 February 2014

FEATURES ● The RCB-1 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 2M. 7M. 10M. 20M. 30M. 50M. 100M. 200M. 500M. 1G. 2G. 5G. 10G. 20G. 50G. 100G. 200G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 5200g...