• Filter
Created on: 20 February 2014

FEATURES ● The RCB-3 is used to verify and proof any High Voltage Insulation   Testers. It can be utilized to calibrate all High Voltage Insulation   Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator   too, therefore, SEW started manufacturing the RCB for special   customers.     SPECIFICATIONS         Resistance ranges (Ω) 1M. 10M. 100M. 1G. 5G. 10G. 100G. 500G Resistance tolerances ±1%(F) Tolerance ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

Created on: 20 February 2014

FEATURES ● The RCB-3-1T is used to verify and proof any High Voltage    Insulation Testers. It can be utilized to calibrate all High Voltage    Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator    too, therefore, SEW started manufacturing the RCB for special    customers.     SPECIFICATIONS Resistance ranges (Ω) 1M. 10M. 100M. 1G. 5G. 10G. 100G. 1T Resistance tolerances ±1%(F) Tolerance  ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 5GΩ. 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

Created on: 20 February 2014

FEATURES ● The RCB-3-1T is used to verify and proof any High Voltage    Insulation Testers. It can be utilized to calibrate all High Voltage    Insulation Testers very accurately Analogs or Digitals.● Some institutions and large industries requested their own calibrator    too, therefore, SEW started manufacturing the RCB for special    customers.     SPECIFICATIONS Resistance ranges (Ω) 1M. 10M. 100M. 1G. 10G. 100G. 1T Resistance tolerances ±1%(F) Tolerance  ± 25ppm/°C : 1MΩ. 2MΩ. 7MΩ. 10MΩ. 20MΩ. 30MΩ. 50MΩ. 100MΩ. 200MΩ. 500MΩ ± 100ppm/°C : 1GΩ. 2GΩ.  ± 200ppm/°C : 10GΩ. 20GΩ. 50GΩ. 100GΩ.  ± 400ppm/°C : 200GΩ. 500GΩ ± 1000ppm/°C : 1TΩ Max. working voltage DC 10kV Operating temperature -30°C~75°C Power coefficient Below 3W Connecting terminals Binding Post : Resistance circuit and guard Dimensions 430(L) × 324(W) × 127(D)mm Weight Approx. 4140g

Created on: 20 February 2014

FEATURES ● The ITC 8 can be utilized to check calibration of resistance ranges   of insulation testers and multimeters.● The resistance checker box is also used to verify insulation testers   and multimeters.     SPECIFICATIONS         Resistance Ranges    0.5Ω, 1Ω, 2Ω, 20Ω, 200Ω, 1kΩ, 10kΩ,    20kΩ, 100kΩ, 1MΩ, 2MΩ, 10MΩ Accuracy    0.5Ω - 2Ω : ± 0.05Ω   20Ω - 10MΩ : ±1% Dimensions 150(L) x 72(W) x 60(D)mm Weight Approx. 180g Safety Standard EN 61010-1 CAT III 1000Vdc

Created on: 20 February 2014

FEATURES ● The 880 AT is a simplified Version of an appliance tester which use    low voltage and low current to perform it's checks.● Application Example   The appliance is plugged into the mini appliance checker, then the   probe make contact with the protective conductor.● Other appliance checking   Washing Machine Toaster Iron Dish Washer   Stove     SPECIFICATIONS       ELECTRICAL       Resistance Ranges    The L-E led will lit when the resistance between Line    to Earth is lower than 1MΩ ±5% .    The N-E led will lit when the resistance between Neutral to Earth is lower    than 1MΩ±5%  The EARTH BOND led will lit when the resistance between the EARTH to the Probe is higher than 10Ω±5% . Test Current    Line to Earth test current is 9uA maximum.    Neutral to Earth test current is 9uA maximum.    Earth to Probe test current is 2.3mA maximum. Maximum...

Created on: 20 February 2014

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS Output voltage H terminal: AC 400V (± 20%) L terminal: AC 100V (± 20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 124(L) × 69(W) × 42(D)mm Weight (battery included) Approx. 305g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

Created on: 20 February 2014

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS         Output voltage H terminal: AC 690V (±20%) L terminal: AC 100V (±20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 128(L) x 72(W) x 45(D)mm Weight (battery included) Approx. 315g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1

Created on: 20 February 2014

FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS         Output voltage H terminal: AC 415V (±20%) L terminal: AC 230V (±20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~ 40°C Dimensions 128(L) x 72(W) x 45(D)mm Weight (battery included) Approx. 315g Power source 9V(6F22) × 1 Safety standard EN 61010-1 EN 61326-1