Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 19 February 2014

FEATURES Lan Cable Tester ● Designed for RJ45/RJ11 modular cables, 10/100   base-T cable and Token Ring cable etc.● The LAN cable tester can verify cable continuity,    open, circuit and miss-wired.  ● The remote receiving unit is available for installed   cables far away either on the wall plates or on the    patch panels.● Auto and manual scan function.● Ground wire test.● Display : LED indication for wire status. Digital Multimeter ● 4000 counts LCD.● Full automatic measurement.   Voltage measurement.   Resistor measurement.● Range change function.● Select function.● Data Hold function.● Continuity check.● Diode measurement.● Low battery indication.● Input impedance:10MΩ.     SPECIFICATIONS   AC Voltage     Range Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+5dgt) 4V 1mV 40V 10mV 400V 100mV 750V 1V DC Voltage     ...

Created on: 19 February 2014

FEATURES ● The 890 PR is a Non-Contact phase detector    with flashing LEDs and a beeping buzzer to    show the detection of AC 3-phase sequence.● Two functions in one unit : open phase and     phase sequence detection.● Convenient brightness switch to make the    indication visible in dim areas or sunlight.● Back cover magnet attaches the instrument to   the AC distribution panel offer easy measurement.● 3-Phase AC 75 to 1000V is fitted for detection.● Detect frequency range is from 45 to 65Hz.     SPECIFICATIONS       Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 4.6±0.1V or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 118(L) × 69(W) × 38(D)mm Weight (battery included) Approx. 370g ...

Created on: 19 February 2014

FEATURES ● Non-contact detector clips. No metal contact points to    advocate greater safety.● Two functions in one unit : open phase and phase   sequence detection.● Designed for checking a wider range of 3-phase power    sources.● LED display lights with buzzer indicator.       ● Brightness button feature for better visibility in dimly lit    areas or sunlight.● Magnetic mounting feature.     SPECIFICATIONS             Measurement principle Static induction Input voltage 75~1000Vac Frequency range 45-65Hz Auto-off 5 min. after power on without detection Low battery warning Power LED flashes at 7V ± 0.2 or less Operating temperature & humidity 0°C ~ 40°C Max. 80% R.H. Storage temperature & humidity -10°C ~ 50°C Max. 80% R.H. Cable length Approx. 800mm Dimensions 128(L) × 72(W) × 44(D)mm Weight (battery included) Approx. 380g Power source 9V (6LF22) × 1 Safety standard EN 61010-1...

Created on: 19 February 2014

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 90V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 510g Safety standard IEC 1010 CAT II 600V

Created on: 19 February 2014

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31

Created on: 19 February 2014

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31

Created on: 19 February 2014

FEATURES ● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.     SPECIFICATIONS       Voltage 200V-600V AC Frequency response 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 530g Safety standard EN 61010-1 CAT Ⅳ 600V EN 61010-2-31

Created on: 19 February 2014

FEATURES ● Three functions in one unit: open phase, phase     sequence and motor rotation indication.    ● Large size alligator clips for easy clipping onto switch-   boards terminals.        ● Highly reliable.     ● Identifies 3 phase sequence and open phase check.● Ideal for installing conveyor lines, pump systems and     interconnected drivers.     SPECIFICATIONS             Input voltage 100-500V AC Frequency range 45-70 Hz Circuit structure All electronic (not mechanical) Power requirement 9V (6F22) × 1 Power consumption Consumption current approx. 14mA of motor rotation field tester AC power consumption Approx. 7mA Dimensions 153(L) × 72(W) × 35(D)mm Weight (battery included) Approx. 200g Safety standard EN 61010-1 CAT III 500V EN 61326-1