Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 20 February 2014

FEATURES ● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded   banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers   and motor coils.     SPECIFICATIONS             AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ˇ LCD backlight display  ˇ Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 430g Power source 9V(6F22) × 1 Safety...

Created on: 20 February 2014

FEATURES ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded    banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers    and motor coils.     SPECIFICATIONS         AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ─── LCD backlight display   ─── Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 420g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN...

Created on: 20 February 2014

FEATURES ● 4000- count LCD.● Full automatic measurement.           ◎ Voltage measurement.           ◎ Current measurement.           ◎ Resistor measurement.           ◎ External frequency measurement.● Range change function.● Data Hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Max/Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded   banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 400.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(1.5%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.0%rdg+3dgt)     40~500Hz DC A 400.0/2000A...

Created on: 20 February 2014

FEATURES ● 2000 - count LCD.● Full automatic measurement.          ◎ Voltage measurement.          ◎ Current measurement.          ◎ Resistor measurement.          ◎ Capacitor measurement          ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded    banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 200.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 200.0mV ±(2.0%rdg+3dgt) 2.000/20.00/200.0/750V ±(1.5%rdg+3dgt) 40~500Hz DC A 200.0/2000A...

Created on: 20 February 2014

FEATURES ● 4000 - count LCD.● Full automatic measurement.      ◎ Voltage measurement.      ◎ Current measurement.      ◎ Resistor measurement.      ◎ Capacitor measurement      ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal parts, shielded    banana plugs and recessed input terminals.     SPECIFICATIONS         AC A 400.0/2000A (40~500Hz) 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) AC V 400.0mV ±(2.0%rdg+3dgt) 4.000/40.00/400.0/750V ±(1.5%rdg+3dgt)     40~500Hz DC A 400.0/2000A 0~1500A           ±(1.5%rdg+4dgt) 1500A~2000A ±(2.5%rdg+4dgt) DC V 400.0mV/4.000/40.00/400.0/1000V...

Created on: 20 February 2014

FEATURES ● Designed for testing AC current and AC voltage.  ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.     SPECIFICATIONS       AC Current     Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage      Ranges AC 200V/AC600V Resolution 0.1V / 1V Accuracy ±(1.5%rdg+3dgt) GENERAL   Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate operating   level ...

Created on: 20 February 2014

FEATURES ● Designed for testing AC current and AC voltage.  ● 5 ranges for AC current testing. ● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.     SPECIFICATIONS       AC Current     Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage      Ranges AC600V / DC600V Resolution 1V /1V Accuracy ±(1.5%rdg+3dgt)/ ±(1.0%rdg+2dgt) GENERAL   Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “  “ sign appears on the display when the battery voltage drops below accurate...

Created on: 20 February 2014

FEATURES ● Easy to read 3-color scale...for mistake proof reading.● Mirror scale...makes reading pointer easy.● Fuse protection function.● Safety fused...on all ranges.● Diode protected meter...prevents damage due to overload.● hFE and db measurement.● With stand...makes reading and measuring easy.     SPECIFICATIONS         DC volts 0-0.1 / 0.5 / 2.5 / 10 / 50 / 250 / 1000V(20kΩ/V) AC volts 0-10 / 50 / 250 / 1000V DC mA 50uA / 2.5 / 25 / 250mA OHMS 2k / 20k / 2M / 20MΩ (20 Mid-Scale) Accuracy ±3% F.S. DC. ± 4% F.S. AC. Sensitivity 20kΩ/V DC. 8kΩ/V AC. dB -10 to ± 50dB hFE 0-1000 ICEO 150uA, 15mA, 150mA LV 3V Dimensions 102(L) × 148(W) × 46(D)mm Weight (battery included) Approx. 300g  Power source 1.5V (AA) × 2 9V(6F22) × 1 Safety standard IEC 1010-1 CAT II 1000V