Products
Sub Categories
Allow you to download data without opening the switch or junction box cover. Any one can steal your power meter until you have this! >> Measures, Stores and Analyzes 144 Different Electical Parameters Including Volts, Amps, Watts, Volt-Amps (VA), Volt-Amps Reactive (VAR), Kilowatts (kW), Kilowatt Hours (kHW), Power Factor and Harmonics through 63rd
Class 0.5 bi-directional energy and full power parameters measurement. Block or Rolling power demand measurement. THD, indivisual harmonics, and sag/swell power quality records. Data logging for alarm, sag, swell events with time-stamped. Report generation for daily and monthly power usage. Communication interfaces:Ethernet, RS485. Communication protocol:Modbus over TCP/IP for Ethernet, Modbus for RS485. Smart Power Meter with up to 4 channels of re-transmission analog outputs for field integration. 12 digital inputs for power system status monitoring. 2 digital relays for kWh pulse or alarm outputs. Automatic detection of voltage & current wiring. Multi-language support.
PRO0030 BASE UNIT POWER AND HARMONICS ANALYZER WITH 3 x 1000A CLAMPS Optional: PRO0041- 3 x 3000A Flexible Clamps Optional: PRO0038- 3 x 100A Clamps
Features: •Analysis for 3 phase multi-power system, 1P/2W, 1P/3W,3P/3W, 3P/4W •3 current probes ( CP-1201 ) are included, if change the current probes, the calibration procedures are not necessary •Current probe input signal/ranges with selection:Input signal (ACV):200 mV/300 mV/500 mV/1 V/2 V/3 VRanges (ACA) : 20 A/200 A/2000 A/30 A/300 A/ 3000 A. •Meter can cooperate the universal current probes •Measurement: V (phase-to-phase), V (phase-to-ground) A (phase-to-ground) KW / KVA / KVAR / PF (phase) KW / KVA / KVAR / PF (system) KWH / KVAH / KVARH / PFH (system) Phase angle •Harmonics display (1-50th order) •Simultaneous display of Harmonics and Wave form •Display of Waveform with Peak Values •Analysis of Total Harmonic Distortion ( THD ) •Graphic Phase diagram with 3-Phase system parameters •3 phase Voltage or Current Unbalanced Ratio ( VUR, AUR ) and Unbalanced Factor •Calculated Unbalanced Current through Neutral Line ( An ) Standard Accessories: * Instruction manual............... 1 PC * Test Leads (TL88-4AT).......... 1 Set (4 PCs) * Alligator clips (TL88-4AC) 1 Set (4 PCs) * Clamp Probe ( CP-1201 )....... 3 PCs * AC to DC 9V adapter..............1...
Features: •Analysis for 3 phase multi-power system, 1P/2W,1P/3W, 3P/3W, 3P/4W •Voltage & Current are the True RMS value. •True Power ( KW、MW、GW ) measurement. •Apparent Power ( KVA、MVA、GVA ) measurement. •Reactive Power ( KVAR MVAR、GVAR) measurement. •Watt-Hour ( WH、SH、QH、PFH ). •Power Factor( PF )、Phase Angle( Φ ). •Voltage measurement range : 10 to 600 ACV •Current measurement range: 0.2A to 1200 ACA. •Programmable CT ratio (1 to 600) and PT ratio (1 to 1000). •ACV input impedance is 10 Mega ohms. •Safety Standard : IEC 1010, CAT III 600V •Built-in clock and Calendar, real time data record with SD memory card , sampling time set from 2 to 7200 seconds. Just slot in the SD card into the computer, it can down load the all the measured value with the time information ( year/month/data/hour/mimute/second ) to the Excel directly, then user can make the further data analysis by themselves. •Measurement: * ACV * ACA * AC WATT ( True Power )AC WATT( Apparent Power )AC WATT( Reactive Power ) * Power factor * Phase angle * Frequency Standard Accessories: * Instruction manual.......................1 PC * Test Leads...
0.1 W resolution ( <1000 W ), high precision and high resolution in the low watt range, good performance , for low power LED lamp watt measurement Supper large LCD, easy to read-out, display the Watt, Power factor, Voltage & Current value at the same time. Accept different kinds current input signal as direct input, inductive clamp probe or CT ( current transformer ). Auto range. Built-in peak hold & data hold function. RS-232 output interface. Power supply by batteries or AC to DC adapter. - See more at: http://www.test-measurement-australia.com.au/electrical/lutron-dw-6090a#sthash.oTAjYKvQ.dpuf Multi-functions: Watt, VA, W hr, Power factor, ACV, ACA, DCV, DCA, Hz, ohm True AC power measurement, not apparent power True RMS for ACV and ACA Display Watt, power factor, V and A simultaneously Auto range, Peak-hold and Data-hold RS-232 serial output interface Watts (AC true power) Direct input: 1W-100kW Current probe: 1W-2,000kW VA(AC) Direct input: 0.01VA-40kVA Power Factor: 0.01-1.00 ACV/DCV 0.1V-600V ACA/DCA Direct input: 0.01A-20A Current probe: 1A-1000A Watt Hour Direct input:...
Thermal Imaging Camera140 x 140 Resolution, 29° × 29° Field of View
Compact Infrared Thermal Imaging Camera100 x 100 resolution, 21° × 21° Field of View

