Sub Categories

our-company.1
Here, you will find out more about our company,KKInstruments. And hopefully, you will get to...
airflow-meters
In engineering, the airflow or air flow is a measurement of the amount of air per unit of time...
cable-tracer-locator
cable is most often two or more wires running side by side and bonded, twisted, or...
cooking-oil-tester
Follow legal stipulations and at the same time save costs in deep-frying. The oil in your...
distance-meters
Distance (or farness) is a numerical description of how far apart objects are. In physics or...
kyn009
Performance characteristics: The box body and the lamp cap shell is made from high strength...
height-gauge
World's best-in-class accuracy 2D measurement systemA sophisticated height gage offering...
high-voltage-testers
The KKInstruments high voltage testing equipment range has been specially designed for the safe and...
hipot-testers
Hipot is an abbreviationhigh potential. Traditionally, hipot is a term given to a class of...
humidity-meters-hygrometers
  Humidity is the amount of water vapor in the air. Water vapor is the gas phase of water and...
impedance-testers
Electrical impedance is the measure of the opposition that a circuit presents to a current when a...
light-lux-meters
The lux (symbol: lx) is the SI unit of illuminance and luminous emittance, measuring luminous flux...
nuclear-radiation-monitor
The Tohoku Earthquake, tsunami and Fukushima Daichi disaster created many challenges for the people...
particle-discharge-pd-tester
The PDSurveyor™ family has been designed to carry out Partial Discharge detection by all...
power-analysers-power-meters
physics, power is the rate at which energy is transferred, used, or...
promotions
For items selling at promotional price, we only accept walk-in, cash and carry from any of...
refractometer
A refractometer is a laboratory or field device for the measurement of an index of refraction...
sound-level-meters
Sound is a sequence of waves of pressure that propagates through compressible media such as air...
thermal-imagers-thermal-camera-infrared-camera
Infrared thermography (IRT), thermal imaging, and thermal video are examples...
thickness-gauges
Application: Accurately measuring remaining wall thickness of metal pipes, tanks, beams, ship...
vibration-meters
Vibration is a mechanical phenomenon whereby oscillations occur about an equilibrium point. The...
water
Water is a chemical compound with the chemical formula H2O. A water molecule contains one oxygen...
  • Filter
Created on: 20 February 2014

FEATURES ● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded   banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers   and motor coils.     SPECIFICATIONS             AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ˇ LCD backlight display  ˇ Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 430g Power source 9V(6F22) × 1 Safety...

Created on: 20 February 2014

FEATURES ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach   places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded   banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers   and motor coils.     SPECIFICATIONS         AC A 400A / 1000A ±(1.5%rdg+3dgt) : 40-500Hz AC V 400V / 600V ±(1.0%rdg+3dgt) : 40-500Hz DC A 400A / 1000A ±(1.5%rdg+3dgt) DC V 400V / 600V ±(0.75%rdg+3dgt)   Ω 400Ω / 2000Ω ±(1.0%rdg+3dgt) Flashlight   ─── LCD backlight display   ─── Buzzer sounds    <38Ω Conductor size 40mm Max. Low battery Indication   Dimensions 255(L) × 80(W) × 35(D)mm Weight (battery included) Approx. 420g Power source 9V(6F22) × 1 Safety standard EN 61010-1 CAT III 600V EN...

Created on: 20 February 2014

FEATURES ● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges     SPECIFICATIONS         AC A 200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz) AC V 200 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz) DC A 200 / 1500A ±(2%rdg+4dgt) DC V 200 / 1000V ±(1%rdg+2dgt)   Ω 200 / 1500Ω ±(1.5%rdg+2dgt) Diode check 0-1500mV ±(1.5%rdg+2dgt) Buzzer Resistance is less than 100Ω Conductor size 55mm Max. Operating temperature 0ºC ~ 40ºC Humidity 85% R.H. Current consumption Approx. 10mA Dimensions 245(L) × 70(W) × 41.7(D)mm Weight (battery Included) Approx. 480g Power source 9V(6F22) × 1

Created on: 20 February 2014

FEATURES ● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges     SPECIFICATIONS         AC A 200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz) AC V 00 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz) DC A 200 / 1500A ±(2%rdg+4dgt) DC V 20 / 200 / 1000V ±(1%rdg+2dgt)   Ω 200 / 1500Ω ±(1.5%rdg+2dgt) Diode check 0-1500mV ±(1.5%rdg+2dgt) Buzzer   ── Conductor size 55mm Max. Operating temperature 0ºC ~ 40ºC Humidity 85% R.H. Current consumption Approx. 10mA Dimensions 245(L) × 70(W) × 41.7(D)mm Weight (battery Included) Approx. 480g Power source 9V(6F22) × 1

Created on: 20 February 2014

FEATURES ● 4000 counts.● Voltage measurement, current measurement, resistor    measurement, frequency counter, capacitor measurement.● Bargraph indication.● Range change function.● Data hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Diode measurement.● Max / Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design throughout with no exposed metal    parts, shielded banana plugs and recessed input terminals.     SPECIFICATIONS       DC Voltage     Ranges Resolution Accuracy 400mV 0.1mV ±(1.0%rdg+3dgt) 4V 1mV 40V 10mV 400V 100mV 600V 1V  ․Overload protection : 650V DC AC Voltage     Ranges Resolution Accuracy 400mV 0.1mV ±(0.5%rdg+3dgt) 4V 1mV ±(1.5%rdg+3dgt) 40V 10mV 400V ...

Created on: 20 February 2014

FEATURES ● Designed for testing AC current and AC voltage.  ● 5 ranges for AC current testing. ● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.     SPECIFICATIONS       AC Current     Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage      Ranges AC600V / DC600V Resolution 1V /1V Accuracy ±(1.5%rdg+3dgt)/ ±(1.0%rdg+2dgt) GENERAL   Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “  “ sign appears on the display when the battery voltage drops below accurate...

Created on: 20 February 2014

FEATURES ● Designed for testing AC current and AC voltage.  ● 5 ranges for AC current testing.● The best resolution of leakage current measurement is 0.1mA.● Frequency selection : 50/60 Hz and Wide.● Data hold function.● Maximum reading.● Low battery indication.     SPECIFICATIONS       AC Current     Ranges Accuracy 50/60Hz WIDE 200mA(0~199.9mA) ±(1.5%rdg+2dgt) 40/1000Hz : ±(3.0%rdg+2dgt) 2A (0~1.999A) 20A(0~19.99A) 200A(0~199.9A) ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 0-500A ±(2.0%rdg+2dgt) 40/1000Hz : ±(3.5%rdg+2dgt) 501-1000A ±5.5%rdg 40/1000Hz : ±10%rdg AC Voltage      Ranges AC 200V/AC600V Resolution 0.1V / 1V Accuracy ±(1.5%rdg+3dgt) GENERAL   Conductor size 55mm Max. Operating principle Dual slope integration Display 3½ digit (2000 counts) Low battery indication “ “ sign appears on the display when the battery voltage drops below accurate operating   level ...

Created on: 20 February 2014

FEATURES ● High quality Taut Band movement.● Easy to read 3-color scale for mistake proof reading.● Mirror scale: makes reading pointer easy.● Safety features on all ranges.● Safety features: safety fused and safety “OFF” position.● dB measurement.● Built-in stand makes reading and measuring easy.     SPECIFICATIONS       DC Voltage     Ranges 0.25 / 1 / 2.5 / 10 / 50 / 250 / 1000V Accuracy ±2% of full scale Sensitivity 50kΩ / V AC Voltage     Ranges 2.5 / 10 / 50 / 250 / 1000V Accuracy ±3% of full scale Sensitivity 10kΩ / V Decibelmeter -20 to 62dB 0dB=1mW / 600Ω Direct Scale:-20 to +10dB DC Current     Ranges 25uA/1mA/25mA/500mA, 10A(on separate input) Accuracy ±2% of full scale Sensitivity 250mV AC Current     Ranges 10A Accuracy ±3% of full scale Resistance     Ranges R × 1           0.2 to 20kΩ R ×...